Description of IO-Link
7100.006434_Bus description_PSD4xx_IO_G_ENG
19
17.08.2020
Tel. +49 7661 39 63-0
info@halstrup-walcher.com
www.halstrup-walcher.com
Designation ISDU
no.
Function
Range of
values
Back
up?
Delivery
state
“Other” parameter group (continuation)
Delivery
state
194
Writing a “-5”:
Resets the drive (corresponds
to switching the control
voltage off and on again)
Writing a “-3”:
Resets all parameters to the
delivery states without saving
the parameters in EEPROM,
without a start-up reference
loop and without positioning
in the middle of the
measurement range.
Writing a “-1”:
Resets all parameters to the
delivery states without saving
the parameters in EEPROM.
The drive then performs a
start-up reference loop and
positions itself in the middle of
the measurement range.
Writing a “0”:
No action
Writing a “1”:
Saves the parameter in
EEPROM
Reading after booting:
0
Memory cont. correct
≠ 0
Memory cont. incorrect
Reading after saving:
0
Saving completed
≠ 0
Saving is not yet
complete or terminated with
errors (saving can take up to
2000ms)
-
5…1
(during
writing)
0...2
(during
reading)
15 bit
No
0
R/W