Description of IO-Link
7100.006434_Bus description_PSD4xx_IO_G_ENG
23
17.08.2020
Tel. +49 7661 39 63-0
info@halstrup-walcher.com
www.halstrup-walcher.com
- as a result of manual rotation when not in operation
Bit 1
:
Reserved
Bit 2
:
Toggle bit
This bit is set:
- if bit 13 of the command byte is set
This bit is reset:
- if bit 13 of the command byte is reset
Bit 3
:
Reserved
Bit 4
:
Motor power present
This bit is set:
- if the supply voltage for the motor is above the UMot limit (ISDU 179)
and under 30V
This bit is reset:
- if the supply voltage for the motor is below the UMot limit or above 30V
Bit 5
:
Positioning run aborted
This bit is set:
- if a positioning run is aborted because the release has been withdrawn
in the command byte
This bit is reset:
- when a new run command is transmitted
Bit 6
:
Drive is running
This bit is set:
- when the drive is rotating
This bit is reset:
- when the drive is at a standstill
Bit 7
:
Temperature exceeded
This bit is set:
- when the internal device temperature exceeds the limit specified in
ISDU 180
This bit is reset: