Description of IO-Link
7100.006434_Bus description_PSD4xx_IO_J_ENG
25
2022-09-13
2.3.
Table of min-, / max- and default values
Note:
The operating current setting is optimised for the nominal rated speed of the
respective device model. The more the set speed deviates from the nominal rated speed
(rpm), the greater the current consumption deviates from the set current value.
Note:
Setting the value for the holding current to 0 results in a current consumption by the
motor circuit of approx. 50 mA.
Device type
PSD
401/411
- 5V
PSD
401/411
- 8H/14H
PSD
403/413
- 8H/14H
PSD
422/432
- 8V
PSD
422/432
- 8H/14H
Name
ISDU
no.
Range of values
Delivery state
Upper
mapping end
120
Min. value = current po 1200 * denominator/numerator
Max. value = current po a * denominator/numerator
Default value =
806,400
806,400
198,498
806,400
806,400
Upper limit
121
Min. value = upper mapping end - a * denominator/numerator
Max. value = upper mapping end - 1200 * denominator/numerator
Default value =
805,200
805,200
197,298
805,200
805,200
Lower limit
122
Min. value = upper mapping end - a * denominator/numerator
Max. value = upper mapping end - 1200 * denominator/numerator
Default value =
-805,200
-805,200
-197,298
-805,200
-805,200
Variable "a"
for formula
(see above)
120-
122
1,611,600
1,611,600
395,797
1,611,600
1,611,600
Target rpm
Positioning
137
1…800
200
1…500
200
1…250
50
1…1000
200
1…500
200
Target rpm,
Manual run
138
1…800
70
1…500
70
1…250
17
1…1000
70
1…500
70
Acceleration
139
1…5000
1000
1…5000
1000
1…1250
250
1
…5000
500
1…5000
500
Deceleration
141
1…5000
2000
1…5000
2000
1…1250
500
1…5000
2000
1…5000
2000
Max. start-up
current
147
5…2000
1000
5…2000
1000
5…2000
1000
5…4000
2000
5…4000
2000