background image

3

 

 

To use the device, visit 

https://

hamsystems.eu

 or download the app for 

your smartphone.

 

For 

Android

https://play.google.com/

store/apps/details?id=com.ham.app

 

For 

iOS

https://itunes.apple.com/us/

app/ham

-

systems/id1262469559

 

Pressing the 

RESET 

will restart your de-

vice (your settings will be preserved).

 

 

Some of our cloud platform features:

 

• 

Monitor and log temperature with high 

resolution

 

• 

Setup alerts when a dry contact chang-
es state, e.g. a door opens

 

• 

Setup alerts when temperature is out 
of the desired range via SMS, e

-

mail, 

phonecalls and push notifications

 

• 

Create interactions between devices in 
an If

-

This

-

Then

-

Than (IFTTT) format.

 

• 

Share device usage with other users.

 

• 

Secured communications with TLS.

 

• 

Organize devices in groups and floor-
plans.

 

USAGE

 

TECHNICAL SPECIFICATIONS

 

Sensors

 

Pt100 3

-

wire for external temperature measurement

 

Internal for temperature and humidity measurement 

 

Resolution

 

Temperature 0.1

o

C, Humidity 0.1%

 

Setting range

 

Pt100: 

-

50

o

C

 με +200

o

C

 

Internal: 

-

10

o

C to +50

o

C and 0%

-

90% RH

 

Accuracy

 

Temperature ± 1 

o

C, Humidity ± 5%

 

Working environment

 

-

10

o

C to +50

o

C, 5%

-

90% RH

 

Number of dry contacts

 

2

 

Power supply

 

5

-

12 VDC, 0.2 A

 

Dimensions

 

21.5 mm x  44.1 mm x 55 mm

 

Case

 

ABS

 

Summary of Contents for ThermoSense

Page 1: ...y through micro USB cable or DC power supply unit RESET and SETUP button Easy installation Up to 2 dry contact inputs for door sensing and more Warranty 2 years 1 P1 probe wire 2 P1 probe wire same color as 1 3 P2 probe wire 4 NC 5 V power supply alternative to micro USB 6 G1 dry contact 1 7 G2 dry contact 2 8 GND dry contact common supply ground negative 9 RESET 10 SETUP 11 Connection Status LED ...

Page 2: ...f the previous steps were successful and the device is connected to the internet then you will be redirected to the a screen where you can monitor your device In case there is an issues on the steps 2 4 5 try pushing the Reset button and wait a few seconds SETUP INSTRUCTIONS SAFETY WARNINGS In case you didn t connect the device correctly it may be damaged or destroyed Recheck your connections befo...

Page 3: ...the desired range via SMS e mail phonecalls and push notifications Create interactions between devices in an If This Then Than IFTTT format Share device usage with other users Secured communications with TLS Organize devices in groups and floor plans USAGE TECHNICAL SPECIFICATIONS Sensors Pt100 3 wire for external temperature measurement Internal for temperature and humidity measurement Resolution...

Page 4: ...chieved is by accessing the router s configuration page If none of the above suggestions worked then repeat the steps 2 5 of the setup instructions The temperature measurement is way off Check that you have connected the PT 100 probe correctly and that there is a good connection between the wires and the terminals Check that the PT 100 probe is not damaged or cut Check that your device is connecte...

Reviews: