background image

g

Operating instruction

10

11

Temperature Sensor

(Batteries inside)

Mounting Accessories

External measuring 

probe

Long Beep

  Press 3 sec. 

Press the zone button

Zone LED fl ashing

Press Learn 

button

Control Panel long beep Zone 

LED fl ashing OFF

1. Introduction

The Temperature Sensor is designed to monitor the temperature of a
specifi c area, whether that is the indoor temperature or outdoor temperature.
It works in conjunction with the AS-200 Series Control Panel. When the 
actual temperature exceeds the preset limit, the control panel will either alert 
you or alarm will be triggered.

In this package, you should fi nd the temperature sensor, 2 lithium batteries
(inside the unit), an external measuring probe for measuring outdoor
temperature and mounting accessories.

Please follow the instructions below to set up the temperature sensor.

2. Learn Sensor to AS-200 Series Control Panel

In order for the sensor to communicate with the control panel properly,
the sensor must be programmed to the control panel. Follow the brief
instructions below or refer to the detail instructions from the AS-200 Series
User’s Instructions to program the sensor to the control panel. Before
proceeding, please remove the battery isolator from the sensor.

Step 1:

Press and hold the Learn Button on the Control Panel for 3 seconds.
Control Panel beeps once and you may release the Learn Button.

Step 2:

Press the zone button (1, 2, 3, or 4) once, for which you want to program
the sensor to. The selected Zone LED will fl ash.

Step 3:

Activate the Temperature Sensor by pressing the learn button (red) on
the Temperature Sensor.

00104989man_de_en_fr.indd   10-11

00104989man_de_en_fr.indd   10-11

02.06.10   08:14

02.06.10   08:14

Summary of Contents for TS-200

Page 1: ...00104989man_de_en_fr indd 2 3 00104989man_de_en_fr indd 2 3 02 06 10 08 14 02 06 10 08 14...

Page 2: ...r Zur Einrichtung des Temperaturmelders folgen Sie den nachstehenden Anweisungen 2 Koppeln des melders mit dem Bedienfeld der AS 200 Serie Damit der Melder ordnungsgem mit dem Bedienfeld kommunizieren...

Page 3: ...e ber bzw unterschreitet wird ein Signal an das Bedienfeld gesendet Um die Grenztemperaturen festzulegen folgen Sie den nachstehenden Anweisungen So legen Sie den oberen Temperaturgrenzwert fest 1 Hal...

Page 4: ...tisches Warnsignal Das Bedienfeld h rt auf zu piepen und zu blinken sobald die Temperatur auf einen zul ssigen Wert zur ckgekehrt ist Wenn z B als oberer Grenzwert 40 C programmiert sind wird ein Sign...

Page 5: ...auf eine Aktivierungspr fung bei verringertem Abstand reagieren tauschen Sie die Batterie des Melders aus Wenn sich mehrere Melder in der betreffenden Zone befinden m ssen Sie eventuell die Funktions...

Page 6: ...mounting accessories Please follow the instructions below to set up the temperature sensor 2 Learn Sensor to AS 200 Series Control Panel In order for the sensor to communicate with the control panel p...

Page 7: ...pper temperature limit 1 Press and hold the HI button 2 While holding on to the HI button press UP or DOWN to select the upper temperature limit 3 Release all buttons after setting the upper temperatu...

Page 8: ...built in temperature sensor An external probe can be used to measure outdoor temperature Temperature sensor must still be mounted indoor Refer to 5 INSTALLATION for further information 5 Installation...

Page 9: ...condition the low battery LED indicator will flash When you see the low battery indication replace the batteries following the procedures below 1 Remove the screw on the back of the temperature sensor...

Page 10: ...es de montage Pour configurer l avertisseur de temp rature suivez les instructions suivantes 2 Couplage du d tecteur avec le panneau de commande s rie AS 200 L avertisseur doit tre programm pour le pa...

Page 11: ...s limites un signal est envoy au panneau de commande Pour d finir les temp ratures limites suivez les instructions suivantes D finition de la valeur limite de temp rature sup rieure 1 Maintenez la tou...

Page 12: ...l avertisseur est r initialis ou lorsque la temp rature revient une valeur autoris e Remarque si le commutateur d avertissement se trouve sur la position Clo che Chime un son de cloche unique retentit...

Page 13: ...panneau de commande et essayez nouveau de l activer Il est possible que l avertisseur soit install trop loin du panneau de commande de sorte que la communication avec ce dernier soit perturb e Dans c...