Chapter 2. Safety and Compliance
EQ-77X LDLS® Operation Manual
7
of
31
WARNING
: The EQ-77X utilizes an internal Class 4 IR laser capable of causing severe injury to eyes or
skin. Do not open or attempt to service this unit. Contact Energetiq
regarding any problems with the
unit.
WARNING
: When working near the emitted light, always wear protective devices (conforming to ISO
4007/4849/4850/4854/4855 or equivalent regulations). The lamp installed in this housing emits intense ultraviolet
rays, which are harmful to the eyes and skin. Looking directly into the emitted light or allowing the light to fall on the
skin will damage eyesight or cause skin burns.
WARNING
: If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
The power supply must be properly grounded by the outlet to prevent electrical shocks.
Securely plug in the power supply connector to avoid looseness or play. Loose connections may result in faulty
operation.
This product is designed and tested for use in an industrial environment. If this product is used in residential areas,
EMI (electro-magnetic interference) may occur.
This product must not be used in residential areas.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note
: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
2.2 Definition of Equipment and Document Symbols and Designations
Do not operate the
EQ-77X if the covers are removed or is defective in any way. Contact Energetiq
if any problems
with the equipment are suspected.
The
EQ-77X utilizes a quartz lamp containing a high-pressure gas fill. Explosion of the lamp and possible injury from
flying fragments can occur if the lamp is mishandled.
Do not open the enclosure of either the lamp or the controller. Dangerous invisible infrared laser beams and
hazardous voltages exist inside the lamp.
Opening the chassis both voids the warranty and exposes the user to
dangerous radiation and hazardous voltages.