Adaptor BNC to 4mm binding posts

HZ22

50

  BNC Feed-through termination 1GHz, 1W

HZ23

Attenuator 2:1, BNC male to BNC female, for oscilloscope service only.

HZ24

Set of 4 BNC  50

Ω  

attenuators; 3/6/10/20dB; 1GHz, 1W, incl. 1x HZ22

Test Cables

HZ32

Test cable  BNC to single stacking banana plugs; 40 inch

HZ33

Coaxial cable BNC/BNC, 50

, 20 inch

HZ33S

Coaxial cable BNC/BNC,  50

, 20 inch, insulated

HZ33W

Coaxial cable BNC/BNC,  50

Ω, 

20 inch, elbow

HZ34

Coaxial cable BNC/BNC,  50

, 40 inch

HZ34S

Coaxial cable BNC/BNC,  50

, 40 inch, insulated

HZ72S

IEEE-488-Bus-Cable, 40 inch. double shielded

HZ72L

IEEE-488-Bus-Cable, 60 inch, double shielded

HZ84-2

Spare Printer Cable  for HD148 (CE) and HM305 / 1007 (CE)

HZ84-3

Spare Printer Cable  for combination of 25pole D-SUB / 26pole plastic male

Wide Band Probes with RF alignment

Type

Attenuation

Bandwidth

Risetime

Input Impedance

Max.

Ratio

Input Voltage

HZ36

1:1/10:1

10/100MHz

<35/3.5ns

1/10M

II57/12pF (10:1) 600V (DC+peak AC)

HZ51

10:1

150MHz

<2.4ns

10M

II12pF

600V (DC+peak AC)

HZ52

10:1

250MHz

<1.4ns

10M

II10pF

600V (DC+peak AC)

HZ53

100:1

100MHz

<3.5ns

100M

II4.5pF

1200V (DC+peak AC)

HZ54

1:1/10:1

10/150MHz

<35/2.4ns

1/10M

II57/12pF (10:1) 600V (DC+peak AC)

Special Probes

HZ38

Demodulator Probe

0.1 - 500MHz

max. 200V (DC)

HZ58

High Voltage Probe, 1000:1; R

i

 

 approx. 500M

; DC - 1MHz

max. 15kV (DC+peak AC)

HZ47

Viewing Hood for Oscilloscopes HM205, 408, 604-1+2, 1005 and 1007

HZ48

Viewing Hood for Oscilloscopes 303, 304, 305, 604-3 and 1004

during transpor-
tation of an oscil-
loscope. It is made
of a durable vinyl-
coated material
that is designed to
withstand the
stress and wear
and tear of field
use.

Specifications:
Current  range:

20A 

DC

 / 30A 

AC

Accuracy:

± 1% ± 2mA

Dielectric strength:

  3.7kV, 50Hz, 1min.

Output sensitivity:

100mV/A

Frequency range:

DC-100kHz

Resolution:

±1mA

Load impedance:

>100k

Divers:

BNC-cable, 2m.

HZ 33

HZ 32

HZ 34S

HZ 72/S/L

HZ 33W

HZ53

HZ54

HZ20

HZ22

HZ23

HZ24

HZ58

Accessories
supplied

HZ39  Spare Cable for HZ36
HZ57
 Spare Cable for HZ51, HZ54
Spare-parts for modular probes only

Spare-part Kit HZ40

HZ96 Carrying Case

for oscilloscopes 

HM203, 205, 208,

408, 604, 1005  

and  

1007

HZ97 Carrying Case

 for 

HM303, 304,

305, 604-3, 1004 

and

 HM5005 / 6 / 10.

The carrying case provides protection

HZ39
HZ57

HZ84-2

HZ36

HZ38

HZ51

HZ52

HZ40

HZ 56 AC/DC Current Probe

Utilising Hall Effect technology to provide a broad frequency response, the
probe will accurately measure AC, DC and complex waveforms. The compact
clip-on design conforms to  the  IEC1010 safety standard and allows non-
intrusive measurement of current from 5mA to 30A peak to an accuracy of
±1%. The probe gives a voltage output directly proportional to the measured
current which is compatible with a wide range of measuring instruments.

Subject to change without notice

05/96

OSCILLOSCOPES

Summary of Contents for HM 303-4

Page 1: ...ge 8 Amplitude Measurements 8 Time Measurements 9 Connection of Test Signal 10 First Time Operation 12 Trace Rotation TR 12 Probe compensation and use 12 Operating Modes of the Y Amplifier 14 X Y Oper...

Page 2: ...ual for a reduced cable length the maximum cable length of a dataline must be less than 3 meters long If an interface has several connectors only one connector must have a connection to a cable Basica...

Page 3: ...WG Low Voltage Equipment Directive 73 23 EEC amended by 93 68 EEC Directive des equipements basse tension 73 23 CEE amend e par 93 68 CEE Angewendete harmonisierte Normen Harmonized standards applied...

Page 4: ...nal Features Component Tester 1kHz 1MHz Calibrator OSCILLOSCOPES Specifications Vertical Deflection Operating modes Channel I or II separate both Channels alternated or chopped Chopper frequency appro...

Page 5: ...prox 500M DC 1MHz max 15kV DC peakAC HZ47 Viewing Hood for Oscilloscopes HM205 408 604 1 2 1005 and 1007 HZ48 Viewing Hood for Oscilloscopes 303 304 305 604 3 and 1004 during transpor tation of an osc...

Page 6: ...is standard It has left the factory in a safe condition This instruction manual contains important information and warnings which have to be followed by the user to ensure safe operation and to retain...

Page 7: ...tment designation isstatedforpossiblequeries thishelpstowards speeding up the processing of guarantee claims Maintenance Variousimportantpropertiesoftheoscilloscopeshouldbe carefully checked at certai...

Page 8: ...However forsignalmagnitudesandvoltage designations in oscilloscope measurements the peak to peak voltage Vpp value is applied The latter corresponds to the real potential difference between the most...

Page 9: ...he attenuator series resistor will break down causingdamagetotheinputoftheoscilloscope However if for example only the residual ripple of a high voltage is to be displayed on the oscilloscope a normal...

Page 10: ...must be divided by 10 The fall time of a pulse can also be measured by using this method The following figure shows correct positioning of the oscilloscope trace for accurate risetime measurement tr...

Page 11: ...obecompensation page M7 Standard attenuator probes on the oscilloscope normally reduce its bandwidth and increase the rise time In all cases where the oscilloscope bandwidth must be fully utilized e g...

Page 12: ...ion required The HM303 accepts all signals from DC direct voltage up to a frequency of at least 30MHz 3dB For sinewave voltages the upper frequency limit will be 50MHz 6dB However in this higher frequ...

Page 13: ...should then be 4 div 0 12div 3 During this adjustment the signal edges will remain invisible Adjustment at 1MHz Probes HZ51 52 and 54 can also be HF compensated They incorporate resonance de emphasing...

Page 14: ...the 3 pushbuttons CH I II DUAL and ADD in the Y field of the front panel For Mono mode all 3 buttons mustbeintheirreleasedpositions onlychannelIcanthen beoperated ThebuttonCHI II TRIG I IImustbedepres...

Page 15: ...in the X Y mode can exceed an angle of 3 above 120 kHz It cannot be seen as a matter of course from the screen display if the test voltage leads or lags the reference voltage A CR network before the...

Page 16: ...o buttons Y CH I 20mV div AC TIME DIV 0 2ms div Triggering NORMAL with LEVEL setting internal or external triggering Figure 2 Amplitude modulated oscillation F 1 MHz f 1 kHz m 50 UT 28 3 mVrms If the...

Page 17: ...ing mode it is possible to trigger at any amplitude point of a signal edge even with very complex signal shapes by adjusting the LEVEL control Its adjusting range is directly dependent on the display...

Page 18: ...eringcanalsobeusefultodisplaysignalsbelowthe triggerthreshold lessthan0 5div Itisthereforeparticularly suitable for measuring small ripple voltages of mains line rectifiers or stray magnetic field in...

Page 19: ...iodes marked OVERSCAN which are located between the attenuators Should one LED illuminate without an input signal this means that the respective vertical positioning control has been improperly adjust...

Page 20: ...orizontal axis and with low values the slope will move towards the vertical axis Values of resistance from 20 to 4 7k can be approxi mately evaluated The determination of actual values will come with...

Page 21: ...n by 180 degrees round about the center point of the scope graticule In Circuit Tests Caution During in circuit tests make sure the circuit is dead No power from mains line or battery and no signal in...

Page 22: ...ort circuit Resistor 510 Junction B C Junction B E Mains transformer prim Capacitor33 F Junction E C FET Z diode below 7V Z diode beyond 7V Diode paralleled by 680 2 Diodes antiparallel Silicon diode...

Page 23: ...n in the edge zone of the screen must be accepted It is limited by standards of the CRT manufacturer The same is valid for tolerances of the orthogonality the undeflected spot position the non lineari...

Page 24: ...anneldisplaywiththe CHI IIbutton is unnecessary it is contained indirectly in the tests above stated input of the vertical amplifier e g using a x1 probe the displayed signal in the50mV div position v...

Page 25: ...splay should not shift horizontally during a change of the trigger coupling from AC to DC with a sine wave signal without DC offset If both vertical inputs are AC coupled to the same signal and both t...

Page 26: ...LDOFF knob Component Tester After pressing the COMP TESTER button a horizontal straight line has to appear immediately when theCOMP TESTER socket is open The length of this trace should be approx 8div...

Page 27: ...d from all voltage sources Normally the capacitors are discharged approx 6 seconds after switching off However with a defective instrument an interruption oftheloadisnotimpossible Therefore afterswitc...

Page 28: ...g Checktoseethatallcircuitboardconnections are making good contact and are not shorting to an adjacent circuit Especially inspect the connections between the PCBs to front chassis parts to CRT PCB to...

Page 29: ...ring TRIG EXT button depressed sync signal 0 3Vpp to 3Vpp to TRIG INP socket Line triggering TRIG selector switch to Select trigger coupling with TRIG selector switch Trigger frequency ranges AC 20Hz...

Page 30: ...nector horizontal deflection in X Y mode Y POS II Controls vertical position knob of channel II display Inoperative in X Y mode POWER Turns scope on and off pushbutton LED LED indicates operating cond...

Page 31: ...1 3 5 6 7 8 9 14 15 16 17 2 4 10 11 12 13 20 21 22 23 24 25 26 27 28 30 31 34 36 37 38 33 32 18 29 19 35...

Reviews: