1. Safety Hints

STOP

 Attention!

 

Fitting or exchanging of an interface must not be 
made unless the oscilloscope or the spectrum 
analyzer is switched off and not connected to line 
(mains).

 

STOP

 Attention!

 

During operation the interface opening must be 
closed.

STOP

 Attention!

 

All interface connections are galvanically connected 
to the scope / to the spectrum analyzer.  

STOP

  Measurement at high potentials is prohibited and en-

dangers the scope / spectrum analyzer, the interface 
and all equipment connected to the interface.  

If the safety rules are disregarded, any damage to HAMEG In-
struments GmbH products will void the warranty. Consequently 
HAMEG Instruments GmbH will not take any responsibility for 
damage to people or equipment of other make. 

2. Interface Description

HO720 is a DUAL Interface that can be used alternatively as a 
USB 2.0 or as a RS-232 Interface in connection with the HAMEG 
CombiScopes HM1008 and HM1508 as well as the HAMEG 
spectrum analyzer HM5530 for data transfer and oscilloscope/
spectrum analyzer control. Only one function (USB or RS-232) 
– not both at the same time – can be activated (see item 5 “Inter-
face Selection”). Both interfaces enable serial data transfer.  

2.1 USB

The interface is equipped with a Type A USB female connector. 
For direct connection with a host controller or an indirect con-
nection via a USB hub, a USB cable is required, equipped with 
Type B male connector one end and a Type A male connector 
at the other. 

2.2 RS-232

The RS-232 connector and its specifi cation comply with the 
interface HO710 that is described in the oscilloscope / spectrum 
analyzer manual. 

3. Firmware

Oscilloscope

3.1  It is absolutely necessary to check the oscilloscope fi rmware 

version before fi tting the Interface HO720. The fi rmware 
version already on the scope is displayed after switching 
on if “Quick Start” is off. The “Quick Start” function can 
be changed after pressing the SETTINGS pushbutton and 
calling “Misc.”.

3.2  If the fi rmware version is 03.000-yy.yyy or higher, continue 

the interface fi tting as described under item 4 (Interface 
Fitting Instruction). In the case of fi rmware versions below 
03.000-yy.yyy, HO720 will not be recognised and a fi rmware 
update is required as described under item 3.3.

3.3  In case of a fi rmware version below 03.000-yy.yyy, please 

download the current fi rmware at www.hameg.com from the 
Internet and update the oscilloscope. The fi rmware can be 
found and downloaded under: Products 

>

 Oscilloscopes 

>

 

(oscilloscope type) 

>

 Software/Firmware (below the oscil-

loscope picture) 

>

 Firmware_HMxxx_Vxxx.zip. 

After receiving the current fi rmware and its installation instruc-
tion, the fi rmware installation must be done via the RS-232 
interface HO710. If the current fi rmware is installed, future 
updates can be made by aid of HO720 too.

Spectrum analyzer

With spectrum analyzers the interface will be recognized by 
each fi rmware version.

 

Type A   

Type B

G e n e r a l  h i n t s          

Summary of Contents for HO720

Page 1: ...D U A L I N T E R F A C E H O 7 2 0 Installation guidelines English Issued September 2006...

Page 2: ...result from such conditions in individual cases HAMEG Instruments GmbH KONFORMIT TSERKL RUNG DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACI N DE CONFORMIDAD Hersteller Manufacturer Fab...

Page 3: ...garding the CE marking 2 1 Safety hints 4 2 Interface description 4 2 1 USB 2 2 RS 232 3 Firmware 4 4 Interface tting instruction 5 4 1 Removing the existing interface 4 2 Fitting the interface HO720...

Page 4: ...via a USB hub a USB cable is required equipped with Type B male connector one end and a Type A male connector at the other 2 2 RS 232 The RS 232 connector and its speci cation comply with the interfac...

Page 5: ...the mea surement inputs STOP Attention To avoid damage of the interface during removing and tting by electrostatic discharge please link a metal part of the oscilloscope spectrum analyzer to equalise...

Page 6: ...isplayed It enables RS 232 interface parameter settings that must correspond with the RS 232 settings in a terminal program or the HMLab settings I n t e r f a c e s e l e c t i o n 5 2 Spectrum analy...

Page 7: ...rdware Wizard is displayed Only in this case the USB Driver must be installed The USB Driver is located in the directory HO720_D2xx_Driver subdirectory Driver 6 1 Installation under Windows XP 6 1 1 P...

Page 8: ...3 4 After the selected path is displayed click Next 6 1 4 Thereafter the Hardware Installation window is displa yed showing a warning to continue the installation procedure As this warning is irrelev...

Page 9: ...Software Firmware below the oscilloscope picture HMLab zip Programming commands The programming commands list will be provided in the Internet under www hameg com 7 2 Spectrum analyzers The interface...

Page 10: ...riestra e 6 A Rohde Schwarz Company D 63533 Mainhausen registered trademark Tel 49 0 61 82 800 0 DQS Certi cation DIN EN ISO 9001 2000 Fax 49 0 61 82 800 100 Reg Nr 071040 QM sales hameg de authorized...

Reviews: