Page 31 of 92
520008300 08/14
SmartServe™ Drink Mixers Service Manual
Removal and Replacement
3. Remove four screws (4) from the panel (5).
4. Carefully lift the panel (5) from the machine.
5. Mark and disconnect two connectors (6) from the interface control board (7).
6. Mark and disconnect three wires (8) from the breaker switch (9).
4
5
9
8
6
7
10
To install the operator interface panel assembly:
1. Ensure the panel gasket (10) is on the machine.
2. Connect three wires (8) to the breaker switch (9).
3. Connect two connectors (6) to the interface control panel (7).
4. Position the panel (5) on the machine and ensure the gasket (10) is seated properly.
5. Install four screws (4) on the panel (5).
6. Close the access door (3).
7. Plug in the power cord to the machine, turn the control panel power switch (1) to the
RESET position, and verify machine operates.
1
3