Bandsaw
N4400
Technical data
The electrical connection may only be carried out by a
competent and qualified person with the appropriate
training.
Ensure that the mains supply is correct for the machine
and use connecting cables with a cross-section appropri-
ate to the power consumption of the drive motor.
The minimum conductor cable size is 2,5 mm for a 400V
supply. If the mains voltage is 230V or has a rated cur-
rent above 15 A, it is necessary to use higher capacity
cabling.
Connect the 3 phases with the R-S-T clamps (L1-L2-L3)
and the yellow-green electrical conductor with the earth-
ing clamp (Pe).
When the machine is first switched on, check the rota-
tional direction and if incorrect, exchange two phases in
4.4 Noise emissions
The given values are emission values and not safe work-
place values. Although there is a correlation between
emission and immission levels, it is not possible to state
whether increased safety measures are required.
Factors which can considerably influence the present
immission level at the workplace include the duration of
exposure, the character of the work area and other influ-
ences in the neighbouring area.
Acceptable workplace values may also vary from country
to country. However, this information should help the user
to better assess the hazards and risks.
Depending on the installation location and other vari-
ables, the resulting noise emission can differ by up to 4
db (A) from the given values.
Type / Model
L Aeq
LW (A)
Lpc
N4400
84,7 dB (A)
97,1 dBw(A)
5,1 mW
< 130 dB (A)
the connection box.
The rotational direction of one phase motors has been
set correctly by the manufacturer.
After connection, check that the connection box and
cable gland have been screwed tightly.
The dust extractor has to be connected to the machine in
such a way as to be operating automatically when the
bandsaw is switched on.
This can for example be achieved by an induction switch
in the machine feed line.