ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
9 of 25
Display function – “
advanced menu
” - submenu “Brushes Sets”
The “
Brushes sets
” submenu allows to enter the parameters and settings related to brush motor.
Brushes Sets:
default
Maximum
current
provided
from
the
electronic card to the brush motor.
Max motor current: ##[Amp]
40
Brushes Sets:
default
Nominal current, joined with T_Nom define
the condition of
Brush Current Protection
.
(alarm + cut off motor).
Nom motor current:##[Amp]
25
Brushes Sets:
default
Nominal timer, joined with I_Nom define the
condition of
Brush Current Protection
. (alarm
+ cut off motor).
Nominal motor time: ##[s]
30
Brushes Sets:
default
Delay in turning off the brush motor at the
release of the pedal.
Swicth off delay: #.#[s]
0,0
Brushes Sets:
Default
Not used.
Reset delay: ##[s]
10
Brushes Sets:
default
Delay in turning on the brush motor at the
pressing of the pedal.
Swicth on delay: #.#[s]
0,2
Brushes Sets:
default
Not used.
Ecomode voltage: ##[V]
17
Press the “key 2” to exit the submenu.
Press the “key 2” to go back to the working mode.