ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
13 of 25
Display function – “
advanced menu
” - submenu “Traction Sets”
The “
Traction sets
” submenu allows to enter the parameters and settings related to traction
motor.
Traction Sets:
default
Acceleration ramp. Time needed to reach
the maximum speed.
Acc Ramp:
#.#[s]
2.5
Traction Sets:
default
Deceleration ramp. Time needed to
completely stop the machine at the
release of the pedal.
Dec Ramp:
#.#[s]
1.0
Traction Sets:
default
Reverse ramp. Time needed to move
from forward to backward, and vice
versa.
Rev Ramp:
#.#[s]
1.0
Traction Sets:
default
Maximum forward speed (as percentage
of the maximum reachable speed).
FW Speed:
#[%]
100
Traction Sets:
default
Maximum
backward
speed
(as
percentage of the
Maximum forward
speed
).
BW Speed:
#[%]
60
Traction Sets:
default
Speed at the minimum pressing of the
pedal.
Min Speed:
#[%]
0
Traction Sets:
default
Minimum potentiometer voltage in idle
condition.
Stop pos ref. value: ##[V]
0.5
Traction Sets:
default
Maximum potentiometer voltage for
forward command.
FW pos ref. value: ##[V]
12.0
Traction Sets:
default
Maximum potentiometer voltage for
backward command.
BW pos ref. value: ##[V]
12.0