ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
14 of 25
Display function – “
advanced menu
” - submenu “Traction Sets” (next)
Traction Sets:
default
Dead band of the potentiometer.
Deadband ref value: ##[mV]
20
Traction Sets:
default
Electronic brake delay at the switching
off of the machine / release of the pedal.
E-Brake Delay:
###[s]
0,5
Traction Sets:
default
Not used.
Model motor voltage: ##[%]
50
Traction Sets:
default
Not used.
Mode1 motor current: ##[A]
35
Traction Sets:
default
Machine breaking when moving switched
on.
Runaway speed: ###[V]
20
Traction Sets:
default
Maximum current provided from the
electronic card to the traction motor.
Max current:
##[A]
45
Traction Sets:
default
Nominal current, joined with T_Nom
define the condition of
Traction Current
Protection
. (alarm + cut off motor).
Nom current:
##[A]
10
Traction Sets:
default
Nominal timer, joined with I_Nom define
the
condition
of
Traction
Current
Protection
. (alarm + cut off motor).
Nom time:
##[s]
10
Press the “key 2” to exit the submenu.
Press the “key 2” to go back to the working mode.