ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
16 of 25
Display function – “
advanced menu
” - submenu “Monitor mode”
The mentioned parameters can be displayed also in working mode. Follow the procedure here
described:
1.
Switch off the machine by switching the key in OFF position.
2.
Enter the “
user menu
”. Press at the same time, with machine off, the “key 4” and the
“key 6”.
3.
Keeping pressed the mentioned buttons, rotate the key in ON position. Wait for the
loading of “
user menu
” text interface.
4.
Once loaded the “
user menu
”, use the “key 1” and the “key 3” to find out the submenu
“
password
”.
5.
Use the “key 4” and the “key 6” to display the value 60 as the standard password to
enter the “
advanced menu
”.
6.
Use the “key 2” to confirm the new parameter value of the password. The “
advanced
menu
” is now accessible.
7.
Use the “key 1” and the “key 3” to find out the submenu “
Check/Monitor
”.
8.
Confirm the access to the submenu “
Check/Monitor
” by pressing the “key 2”.
9.
Use the “key 1” and the “key 3” to visualize the parameter to be monitored in working
mode.
10. Confirm the parameter to be monitored by pressing the “key 2”.
11. Once confirmed the display will came back to “
advanced menu
”.
12. Press the “key 1” and the “key 3” to find out the submenu “
Exitr
”.
13. It is possible to use and works with the machine as usual and monitoring at the same
time the status of the parameter.
14. To exit the submenu “
Check/Monitor
” switch off and switch on the machine.