ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
18 of 25
Battery charger adjustment (NORDELETTRONICA)
1. Check that the set-up of the battery charger corresponds to
the type of battery actually installed on the machine.
2. To adjust the battery charger, proceed as follows:
•
Use a screwdriver to remove the small
plastic cap,
•
Set the dip switch in accordance with the following tables,
•
Fix again the small
plastic cap
.
Use only the
upper dip switch
, check that the
lower ones
are
both OFF.
Set the upper dip switches as follows
S1
S2
SET UP
FLASHES
OFF
OFF
Wet cell batteries
1
ON
ON
Gel TROJAN
2
OFF
ON
Generic GEL or AGM batteries
3
ON
OFF
Gel EXIDE SONNENSCHEIN
4
SW2
:
S3
e
S4
:
OFF for all batteries (not used)
Carefully read the battery charger operating
manual.
Battery charger alarm signals:
YELLOW LED
1 Flash:
WRONG BATTERY - POLARITY REVERSAL -
SHORT CIRCUIT OUTPUT;
2 Flashes: ALARM TIME-OUT, DEFECTIVE BATTERY
3 Flashes: DEFECTIVE CHARGER
4 Flashes: OVERHEATING ALARM
Initial test of the charger:
When plugged in, the Red LED lit once, than the Yellow LED lit
once, and then the green LED flashes to confirm which
charging algorithm was selected by the dip switches (see
table).