ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
21 of 25
7.
Suction microswitch
adjustment:
•
adjust the microswitch so that when the lever is turned,
the switch closes (thereby activating the suction).
•
Once find the correct regulation fix the microswith with
the fixing
screw and nut
.
after adjusting, check the microswitch is functioning correctly.
Check electrobrake
Check the functionality of electronic brake :
Lever raised up (electronic brake on).
-
The electronic brake must switch on automatically if the
machine is off and if it is placed in incline. Once the
electronic brake is switched on the
machine has to resist
to motion
and the buzzer must be on.
-
With the key in ON position the motion (by drive pedal)
must be disabled.
Lever raised down (electronic brake off).
-
Check the functioning of the electronic brake at the pushing
of the emergency button.
ECO Function testing
1. The noise of suction motor must decrease with
Eco
function
on.
ATTENTION
. Precise power consumption and noise values are
not provided since they are affected by the working and
operating conditions.