ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
5 of 25
Display function – “
user
menu
” and “
advanced menu
” (following)
Available sections of
“
user menu
”
are:
MENU
DEFAULT
AVAILABLE
VALUES
DESCRIPTION
General Sets:
Language: ###
IT
IT – EN – DE – FR -
SP
Language setup.
General Sets:
Model: ###
ANTEA
B-BT-B DS-BT DS-
VERSA-VERSA DS
Machine model setup.
General Sets:
Battery: ###
GEL
WET – GEL – XFC Installed batteries type.
General Sets:
Reset main count-meter: ###
NO RESET
Y/N
Reset for partial hour
meter.
General Sets:
Display count-meter: ###
Traction
Traction / Key
Hourmeter mode:
key
–
connected
to
ON/OFF key.
Traction
– connected to
traction motor.
General Sets:
Display tune: ###
15
5 - 50
Display tune
General Sets:
Display brightness: ###
0
0 – 10
Display brightness
General Sets:
Exit: ###
N
Y/N
Exit from ”
user menu
”
General Sets:
Key-on ctn: ###h:###m
-
-
General hour meter for
turning on status.
General Sets:
Traction motor_h: ###h:###m
-
-
General hour meter for
traction motor use.
General Sets:
Brush motor_h: ###h:###m
-
-
General hour meter for
brush motor use.
General Sets:
Vacuum motor_h: ###h:###m
-
-
General hour meter for
vacuum motor use.
General Sets:
-ID CHECK- Password: ###
-
-
Password to get access to
“
advanced
menu
”,
only
for
experienced
technicians.
Default
password is 60.