ADJUSTMENTS
AND
TESTING
ANTEA 50 BT – BTS - BTO
Doc.
10059284
Issued
12/2016
Ver.
AC
Page
7 of 25
Display function – “
user
menu
” and “
advanced menu
” (next)
“
Advanced menu
”.
To get access to the “
advanced menu
” enter as first the “
user menu”
and then the submenu
“
password
”.
Type in the value
60
. The available submenu are:
Settings:
Access to general settings (language,battery type…)
>General sets.
Settings:
Access to parameters related to brush motor.
>Brushes sets.
Settings:
Access to parameters related to dosing system as
water pump (if included).
>Water Pumps sets.
Settings:
Access to parameters related to dosing system as
detergent pump (if included).
>Chemical sets.
Settings:
Access to parameters related to vacuum motor.
>Vacuum sets.
Settings:
Access to parameters related to traction motor.
>Traction sets.
Settings:
Monitor of machine working parameters.
>Monitor mode.
Settings:
Factory default settings.
Do not modify anything.
Contact Fimap Service.
>Engineer pars.
Settings:
Back to the main page.
>Exit…..
Use the “key 1” and the “key 3” to move into the submenu of the “
advanced menu
”
Use the “key 2” to enter a submenu and to confirm a new parameter value.
Use the “key 4” and the “key 6” to modify a setting.
Use the “key 2” to leave the “
advanced menu
” and get back to the working mode.