HG2200/HG2200AT Operator’s
Manual
200 Hour
120 - Service
200 Hour
Change Hydraulic Fluid Filter
Change hydraulic fluid filter after 200 hours or as
indicated by the hydraulic fluid filter restriction
indicator. See “Hydraulic fluid filter restriction
To change:
1. Turn filter (shown) counterclockwise to
remove.
2. Clean filter head surface.
3. Apply thin film of oil to gasket of new filter.
4. Install filter, turning clockwise by hand until
filter head contacts the filter head surface.
5. Start engine and cycle control levers to pressurize system.
6. Stop engine, check hydraulic fluid level, and check for leaks around filter.
Change Fuel Filter
Change fuel filter every 200 hours.
1. Close fuel shutoff valve (1).
2. Replace fuel filter (2).
3. Open fuel shutoff valve.