HG2200/HG2200AT Operator’s
Manual
100 Hour
118 - Service
100 Hour
Change Engine Oil and Filter
Change engine oil and filter every 100 hours.
To change:
1. While oil is warm, remove drain plug (3). Drain
oil and replace plug.
2. Remove filter (1) and replace with new filter
each time oil is changed.
3. Add DEO at fill (2) until oil level is at highest
capacity on dipstick.
Check Fan Belt
Check alternator fan belt tension every 100 hours.
1. Apply pressure to fan belt (2) between pulleys.
Belt should move between 0.28-0.35” (7-9
mm) when pressed.
2. If the belt is outside of normal tension adjust
alternator arm (1) until belt is within normal
limits.
3. Replace fan belt if damaged.
Task
Notes
Change engine oil and filter
DEO
Check fan belt
Check battery
j64om043w.eps
2
3
1
j64om044w.eps
1
2
Summary of Contents for HG2200
Page 51: ...HG2200 HG2200AT Operator s Manual Battery Disconnect 50 Controls ...
Page 75: ...HG2200 HG2200AT Operator s Manual Retrieve Tracked Unit 74 Transport ...
Page 87: ...HG2200 HG2200AT Operator s Manual Finish Installation 86 Burst Pipe ...
Page 129: ...HG2200 HG2200AT Operator s Manual As Needed 128 Service ...
Page 133: ...HG2200 HG2200AT Operator s Manual Declaration of Conformity Information 132 Specifications ...
Page 137: ...HG2200 HG2200AT Operator s Manual 136 Service Record Service Performed Date Hours ...
Page 146: ......