HG2200/HG2200AT Operator’s Manual
Electric Strike System (ESID)
Systems and Equipment - 95
Test Strike System
If system fails any part of this test, see “Troubleshoot Strike System” on the following page. Do not winch
until test is completed successfully.
1. Turn on unit. “Start Unit” on page 64
2. ESID control module will perform internal tests which check everything but alarms and strobe.
3. If green OK indicator and electrical power supply indicator lights remain on, press self test button to
perform total test of strike system. During this test:
•
All lights should glow.
•
Alphanumeric readout should display numbers.
•
Alarms and strobes on all connected units should sound.
4. If this test is successful, OK indicator and electrical power supply indicator lights will remain on.
5. Use Electric Strike Simulator to test voltage and current sensors. See page 99.
ESID Diagnostic Codes
When strike system detects a problem, an error code will be displayed. Anytime this happens, press self-
test button to retest. If error code is still displayed and does not appear in this chart, have control module
checked or replaced.
Code
Display
Condition
Result
502
2.5V REF
2.5V reference error in ESID
Internal reference failure, ESID may
not give valid readings
503
-5V REF
-5V reference error in ESID
internal reference failure, ESID may
not give valid readings
504
CLK RESP
clock response error
clock my not be working
505
LCD RESP
LCD response error
LCD display my not work
506
LED RESP
LED response error
LED display my not work
507
LCD CONTR
LCD contrast error
LCD contrast not saved properly
508
COP RESET
cop watchdog error
processor has reset, unknown status
of ESID code
510
STRB DVR
strobe driver output error
strobe may not function
511
HORN DVR
horn driver output error
horn may not function
512
BAT POWER
battery power/horn driver error
strike hold on power may not
function
513
TEST WIRE
no continuity on test wire for
testing ESID
information center may not be able
to reset ESID
515
STR VOLT
strike voltage input error
Summary of Contents for HG2200
Page 51: ...HG2200 HG2200AT Operator s Manual Battery Disconnect 50 Controls ...
Page 75: ...HG2200 HG2200AT Operator s Manual Retrieve Tracked Unit 74 Transport ...
Page 87: ...HG2200 HG2200AT Operator s Manual Finish Installation 86 Burst Pipe ...
Page 129: ...HG2200 HG2200AT Operator s Manual As Needed 128 Service ...
Page 133: ...HG2200 HG2200AT Operator s Manual Declaration of Conformity Information 132 Specifications ...
Page 137: ...HG2200 HG2200AT Operator s Manual 136 Service Record Service Performed Date Hours ...
Page 146: ......