HG2200/HG2200AT Operator’s Manual
Plan Pull Path
58 - Prepare
Plan Pull Path
Plan the pull path, from entry to end, before job begins. Locate the entire route of the pipe to be replaced to
ensure a straight path. Expose all crossing or parallel utilities in accordance with local regulations.
Prepare Jobsite
Mark Pull Path
Mark your planned pull path with white flags or paint.
Jobsite hazards could cause death or serious injury. Use
correct equipment and work methods. Use and maintain proper safety
equipment.
274-050; 274-724 (2P), 700-133
To help avoid injury:
•
If jobsite classification is in question or the possibility of unmarked electric utilities exists, classify
jobsite as electric.
•
Cutting high voltage cable can cause electrocution. Expose lines by hand before digging.
•
All vegetation near operator’s station must be removed. Contact with trees, shrubs, or weeds during
electrical strike could result in electrocution.