HG2200/HG2200AT Operator’s Manual
Electric Strike System (ESID)
Systems and Equipment - 99
Use Electric Strike Simulator
Use the Electric Strike Simulator to test voltage and current sensors on ESID. If readings are less than
indicated here, replace 9V battery in simulator and retest. If readings are still less than indicated, contact
your HammerHead
®
dealer to have ESID repaired before winching.
Current Test
To test for current at normal levels:
1. Thread one lead wire through current transformer.
2. Clip ends of lead wires together to make one loop.
3. Move simulator switch to "current" and press test button.
4. Watch screen and lights above display on strike system.
•
Three or four lights should turn on.
•
Current "A" should show 30% or higher in display.
To test for current at strike levels:
1. Put two or three loops through current transformer.
2. Follow steps above to test.
3. Display should show the following:
•
All lights should turn on.
•
Alarm and strobe should turn on.
With two loops,
•
Current "A" should be 80% or higher.
•
Strike indication might go on and off.
With three loops,
•
Current should be 130% or higher.
•
Strike indication should be continuous.
Summary of Contents for HG2200AT
Page 51: ...HG2200 HG2200AT Operator s Manual Battery Disconnect 50 Controls...
Page 75: ...HG2200 HG2200AT Operator s Manual Retrieve Tracked Unit 74 Transport...
Page 87: ...HG2200 HG2200AT Operator s Manual Finish Installation 86 Burst Pipe...
Page 129: ...HG2200 HG2200AT Operator s Manual As Needed 128 Service...
Page 133: ...HG2200 HG2200AT Operator s Manual Declaration of Conformity Information 132 Specifications...
Page 137: ...HG2200 HG2200AT Operator s Manual 136 Service Record Service Performed Date Hours...
Page 146: ......