HAMMOND
MANUFACTURING
TM
TOOL BOX
BUL86393
PMHGY - SERIES
ASSEMBLY INSTRUCTIONS FOR
PMHGY - EJ and 1414
REV. B
PAGE 1 OF 2
1
2
3
4
5
7
8
9
6
ITEM No.
DESCRIPTION
QTY
1
PMV....GY - Vertical Rail
1
2
PMH..GY - Horizontal Rail
2
3
3/8"-16 X 3/4" Bolt ZP
2
4
3/8" Split Lock Washer ZP
2
5
3/8"-16 Hex Nut ZP
2
6
PMSTRAP
4
7
5/16"-18 X 1" Bolt ZP
4
8
5/16" Split Lock Washer ZP
4
9
5/16"-18 Hex Nut ZP
4
SOLD
SEPERATELY
SOLD
SEPERATELY
POLE
ASSEMBLY INSTRUCTIONS:
A) Measure distance between vertical mounting centers on enclosure.
B) Layout PMH..GY (item 2) centered on PMV....GY (item 1) with the distance
measured in step A. EJ enclosures must use top hole, 1414 enclosures use the center
hole.
C) Use 3/8" x 3/4" bolt (item 3) with split lock washer (item 4) and 3/8" nut (item 5) to
PMH..GY (item 2) to PMV....GY (item 1). Tighten down.
D) Attach assembly to pole using PMSTRAP40 (up to 10" diameter pole) or
PMSTRAP55 (up to 12" diameter pole).
E) Attach enclosure to pole mount assembly using 5/16" x 1" bolts (item 7) 5/16" split
lock washer (item 8) and 5/16" hex nut (item 9).
EJ MOUNTING HOLE
1414
MOUNTING HOLE
Tape
Measure
9/16" Socket
Wrench
1/2" Socket
Wrench
www.hammondmfg.com