PARTS INCLUDED FOR INSTALLATION (parts are not to
scale):
INSTALLATION INSTRUCTIONS:
1. Select the desired installation location. Run supply wires from the breaker
panel to the desired location and prepare the concrete surface. (If you are
unfamiliar with proper electrical practices, obtain services of a qualified
electrician.) When preparing the concrete surface, be sure that the Wire
Conduit (#27), protecting the supply wires, extends 1/2” above the Concrete
Surface (#28) to prevent any runoff from entering. Using the provided
Template (#29), mark the locations for the mounting holes. At the marked
locations, drill ½” diameter Holes (#30) approximately 3” deep. Do not
exceed a 3” depth.
(Fig. 9)
2. Insert the Anchors (#31) into the Holes (#30).
(Fig. 10)
3. Using the provided Wire Nuts (#9), make the following wire connections
(Fig.
11)
:
White Extension Wire (#7)
to
White (Neutral) Supply Wire (#33)
Black Extension Wire (#8)
to
Black (Hot) Supply Wire (#34)
Fixture Ground Wire (#15)
to
Supply Ground Wire (#35)
3 ea Wire Nuts (#9)
3 ea Anchors (#31)
3 ea Flat Washers (#36)
3 ea Lock Washers (#37)
3 ea Hex Nuts (#38)
1 ea Template (#29)