3
HAMPTONBAY.COM
Please contact 1-855-HD-HAMPTON for further assistance.
Product Specification
Typical Installation
Wiring Diagram
SPECIFICATIONS
SPECIFICATIONS
Airflow: 80 CFM
Power consumption: 12 W
120 V, 60 Hz
Weight: 4.00 lbs.
Duct diameter: 4 in.
Ceiling Opening Dimension Requirements: 7-1/2 in. (L) x 7-1/4 in. (W)
x 5-3/4 in. (H)
Sound output: 1.5 Sones
QUICK CONNECTOR INSTRUCTIONS
To be sold only with installation instructions.
WARNING:
Wiring must comply with all applicable electrical
codes. Turn OFF power before removing or installing connectors.
WARNING:
COPPER TO COPPER ONLY. Do not use Aluminum wire.
CAUTION:
Accessory part (quick connector) should meet
installation instructions below.
NOTE:
The connector is reusable on solid wires of the same wire gage or
smaller. Do not reuse the connector on stranded wires.
• Strip wires 3/8"-1/2"
• Grip the wire firmly and push
the stripped end of the wire into
the open port of the connector.
Use only one conductor
per port.
• Verify the stripped end of the
wires is fully inserted to the
back of the connector.
Quick
connect
House
wires
Product
wires
NOTE:
Important wire information. Maximum temperature rating 105˚C
(221˚F). 600 volts maximum for building wire and 1000 volts maximum for
building wire and 1000 volts maximum in signs and lighting fixtures.
The acceptable wire range includes: Solid: 12-18 AWG.
The ducting from this fan to the outside of the
building has a strong effect on the air flow, noise and
energy use of the fan. Use the shortest, straightest
duct routing possible for best performance, and
avoid installing the fan with smaller ducts than
recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans
installed with existing ducts may not achieve
their rated air flow.