background image

 

4

 
 
 
 
 
 
 
 
 
                                                                                                                                                                                                             
 
 
 

                                                                                            
 

 

FIG. 2                                                                                                          FIG. 3

 

STEP 3: 
ELECTRICAL CONNECTIONS 

1.

 

When removing the supply wires from the ceiling outlet box the white supply and green (or bare copper) ground 
wire should be on one side of the track and the black supply wire should be on the other. 

2.

 

Connect the white wire (neutral or common) from the supply circuit to the white from the floating live-end 
connector. Connect the black (hot) wire from the supply circuit to the black wire from the floating live-end 
connector. Connect the green or bare copper ground wire from the supply circuit to the green conductor of the 
floating live-end connector. Secure splices with UL Listed wire connectors suitable for the size, type and number 
of conductors. (see Figure4.) 

3.

 

Carefully push the leads into the ceiling outlet box. Tighten the toggle bolts and attach the plastic floating live-end 
connector canopy with the screws provided.      

             
 
 
 
 
 
 
 

FIG. 4    

 

 
 
 
 
 
 
                                                                      

STEP 4:  
ATTACH TRACK TO CEILING 

Please Note: If you are connecting 2 track sections together start with Point #1(Not provided on all models),otherwise 
start with Point#2. 
1.

 

Using the straight connector – IMPORTANT: Determine ground side of track (has indented groove on face and 
two internal copper bars) and connector (side of connector with two metal tabs).Can only be assembled if grounds 
are aligned.  

a. Loosen set screw on end cap at appropriate track ends and remove. Loosen set screws on connector. 

b. Aligning the ground sides of the track and connector, push the connector into open ends of track. Tighten set 

screws.(see figure 5)

 

2.

 

Raise the track assembly to the ceiling. Mark the mounting holes locations with a pencil. Insure the floating live-
end connector body is positioned over the ceiling outlet box. 

3.

 

Drill holes suitable for the fasteners you will be using. Toggle bolts supplied with the track requires 5/8 inches 

hole. 

4.

 

Insert the toggle bolts through the holes near the ends of the track. Screw bolts into the toggle wings two or three 

turns. 

5.

 

Push toggle bolts into the holes drilled into the ceiling and tighten toggle bolts until the track is about 1/4 inch 

from the ceiling. Do not fully tighten toggle bolts until after electrical connections are made. 

 
 
 
 
 
 
 
 
 
 
 

  FIG. 5 

 
 
 
 

BLACK 

GROUND 

WHITE 

FLOATING LIVE-END 
CONNECTOR 

TAB 

TRACK SECTION

INDENTATION 

MOUNTING PLATE 

SCREW 

WHITE 

BLACK

GREEN 

WIRE CONNECTOR  

OUTLET BOX 

BLACK (HOT)

WHITE (NEUTRAL) 

 

GREEN (GROUND)

MOUNTING PLATE  

WHITE

GREEN

BLACK

Set screws

track 

Ground conductor 
tab on this side 

Ground groove side  

Summary of Contents for 413-994

Page 1: ...1 INSTRUCTION MANUAL 3Light Linear Track lighting Kit Brushed Steel Finish Home Depot SKU 413 994 UPC008938734721 Home Depot SKU 672 841 UPC008938234726...

Page 2: ...BE FOLLOWED INCLUDING THE FOLLOWING 1 Read all instructions Save these instructions and refer to them when additions to or changes in the track configuration are made 2 Do not install this lighting sy...

Page 3: ...s described above INSTALLATION INSTRUCTIONS AS SHOWN IN DIAGRAM FIG 1 STEP 1 CONNECT FLOATING LIVE END CONNECTOR TO TRACK 1 The track section and floating live end connector must be assembled so that...

Page 4: ...ck has indented groove on face and two internal copper bars and connector side of connector with two metal tabs Can only be assembled if grounds are aligned a Loosen set screw on end cap at appropriat...

Page 5: ...d of five 5 years from date of purchase This warranty applies only to the original consumer purchaser and only to products used in normal use and service If this product is found to be defective the m...

Page 6: ...6 MANUEL D INSTRUCTIONS clairage lin aire triple sur rail Fini a Cier Bross Home Depot UGS 413 994 CUP 008938734721 Home Depot UGS 672 841 CUP 008938234726...

Page 7: ...uctions Conserver ces instructions et les consulter dans l ventualit d ajouts ou de modifications apport s au rail d clairage 2 Ne pas installer ce syst me d clairage dans un endroit humide ou mouill...

Page 8: ...ON Faire attention de ne pas endommager les isolateurs des barres omnibus pendant le per age Si des isolateurs subissent des dommages jeter la section de rail Pour pr venir les risques d incendie ou d...

Page 9: ...LAU PLAFOND Veuillez noter Si vous reliez ensemble 2 sections de rail commencez par le num ro 1 non fourni sur certains mod les autrement commencez par le num ro 2 1 l aide du raccord droit IMPORTANT...

Page 10: ...uit sera exempt de d faut de fabrication et de mat riaux pendant une p riode de cinq 5 ans compter de la date d achat Cette garantie ne vise que l acheteur original et uniquement un usage et un entret...

Page 11: ...11 MANUAL DE INSTRUCCIONES Kit de 3 Luces de Riel Lineal Acabado en Acero Cepillado Home Depot SKU 413 994 UPC008938734721 Home Depot SKU 672 841 UPC008938234726...

Page 12: ...UCIONES B SICAS DE SEGURIDAD INCLUIDAS LAS SIGUIENTES 1 Lee todas las instrucciones Guarda estas instrucciones y cons ltalas cuando hagas cambios o cuando ampl es la configuraci n del riel 2 No instal...

Page 13: ...rificio a trav s del canal del riel PRECAUCI N Ten cuidado de no da ar los aislantes de la barra de distribuci n al taladrar Si accidentalmente da as alg n aislante desecha la secci n del riel Para ev...

Page 14: ...isto con todos los modelos o de lo contrario comience con el punto 2 1 Usando el conector recto IMPORTANTE Ubique el lado de conexi n de tierra del riel tiene una ranura y dos barras de cobre internas...

Page 15: ...5 a os a partir de la fecha de compra Esta garant a es v lida s lo para el comprador original y s lo cubre los productos de uso y funciones normales Si se descubre alg n defecto en este producto la n...

Reviews: