Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 12

Care and Cleaning ............................................................. 13

Troubleshooting ................................................................. 13

1. 

To reduce the risk of electric shock, ensure the electricity has 
been turned off at the circuit breaker or fuse box before you 
begin.

2. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70-1999 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

3. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only 
UL Listed outlet boxes marked “Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less.”

4. 

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are 
in motion. You must turn the fan off and stop the blades before 
you reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, 
use caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are 
not packed with the fan must be UL-Listed and marked suitable 
for use with the model fan you are installing. If using this fan 
in a wet or damp environment, the light kit must be marked 
“Suitable for Use in Wet Location”. Refer to the instructions 
packaged with the light kits and switches for proper assembly.

9. 

This product is suitable for use in wet locations when installed 
in a GFCI protected branch circuit.

10. 

All setscrews must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury, do 

not bend the blade brackets (also referred to as 

flanges) during assembly or after installation. Do not 

insert objects in the path of the blades.

WARNING:

 To reduce the risk of fire, electric shock 

or personal injury, mount to outlet box marked 

“acceptable for fan support of 35lbs. (15.9 Kg) or 

less” and use screws provided with the outlet box.

WARNING:

 Remove the rubber motor stops on the 

bottom of the fan before installing the blades or 

testing the motor.

WARNING:

 To reduce the risk of fire or electric shock, 

do not use this fan with any solid-state speed control 

device.

WARNING:

 To avoid possible electrical shock, turn 

the electricity off at the main fuse box before 

wiring. If you feel you do not have enough electrical 

wiring knowledge or experience, contact a licensed 

electrician.

WARNING:

 Electrical diagrams are for reference only. 

Optional use of any light kit shall be UL-Listed and 

marked suitable for use with this fan.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury, use 

only the screws provided with the outlet box.

Summary of Contents for 48-PB

Page 1: ...gh the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Hampton Bay To view an instructional video on how to install this product 1 Go to www homedepot com and enter either the Item or Model number found in the top right corner...

Page 2: ...nstalling If using this fan in a wet or damp environment the light kit must be marked Suitable for Use in Wet Location Refer to the instructions packaged with the light kits and switches for proper assembly 9 This product is suitable for use in wet locations when installed in a GFCI protected branch circuit 10 All setscrews must be checked and retightened where necessary before installation WARNIN...

Page 3: ...ll render the warranty invalid There is no other express warranty Hampton Bay hereby disclaims any and all warranties including but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law The duration of any implied warranty which cannot be disclaimed is limited to the time period as specified in the express warranty Some states do not allow a li...

Page 4: ...nuts 3 CC Hanger pin 1 DD Locking pin 1 Part Description Quantity EE Rubber gasket for close to ceiling mounting 1 FF Extra blade bracket attachment hardware 1 GG Pull chain 1 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA BB CC DD EE FF GG ...

Page 5: ...ttached 1 D Fan motor assembly 1 Part Description Quantity E Switch cup 1 F Decorative motor collar cover 1 G Blade bracket flange screws pre installed 5 H Blade 5 IMPORTANT This product and or components are governed by one or more of the following U S Patents 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 and other patents pending Pre Installation continued PACKAGE CONTENTS A B D E F G H C ...

Page 6: ...se the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs 15 9 kg Do not use a plastic outlet box The illustrations below show three different ways to mount the outlet box If the canopy touches the downrod then remove the decorative canopy bottom cover and turn the canopy 180 before attaching the canopy to t...

Page 7: ...s locked position Re tighten the setscrews on the collar MM on top of the fan motor housing D Remove the canopy ring JJ from the canopy C by turning the ring counterclockwise until it unlocks Remove the mounting bracket A from the canopy C by loosening the two canopy screws HH located in the L shaped slots Remove and save the two canopy screws II in the round holes This will enable you to remove t...

Page 8: ...tor collar MM to the top of the fan motor housing D Place the rubber gasket EE over the remaining three screws route the wires exiting the top of the fan motor housing through the canopy ring JJ make sure the slot opening are on top then proceed to place the ceiling canopy C over the collar at the top of the fan motor housing D Align the mounting holes with the holes in the fan motor housing D and...

Page 9: ... wire using a wire connecting nut BB Connect the fan motor black and blue wires to the household black wire using a wire connecting nut BB Secure each wire connecting nut BB using electrical tape Turn the wire connecting nut BB upward and push the wiring into the outlet box RR 6 IMPORTANT Use the wire connecting nuts BB supplied with your fan Secure the connectors with electrical tape and ensure t...

Page 10: ... fan from the slide on mounting bracket A and align the locking slots of the ceiling canopy C with the two screws HH in the slide on mounting bracket A Push up to engage the slots and turn clockwise to lock in place Immediately tighten the two mounting screws HH firmly Install the remaining two mounting screws II into the holes in the canopy C and tighten firmly Install the decorative canopy ring ...

Page 11: ... blade H and blade bracket G Fasten the blade assemblies to the fan motor assembly D by inserting the alignment post into the slot on the bottom of the motor and tightening the pre installed blade bracket screws TT by inserting a screwdriver through the access hole ZZ Repeat this step for the remaining blade assemblies by rotating the motor until the next blade bracket screw can be accessed throug...

Page 12: ...rols the direction forward switch left or reverse switch right Warm weather Forward A downward airflow creates a cooling effect This allows you to set your air conditioner on a higher setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a lower setting without affecting your comfort NOTE Wait for...

Page 13: ... above the tip of one of the blades Measure from a point on the center of each blade to the point on the ceiling Measure this distance Rotate the fan until the next blade is positioned for measurement Repeat for each blade Any measurement deviation should be within 1 8 in Run the fan for ten minutes Run the fan for ten minutes If the fan continues to wobble please contact Customer Service and a ba...

Page 14: ...ns problems missing parts Before returning to the store call Hampton Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD HAMPTON HAMPTONBAY COM Retain this manual for future use ...

Page 15: ...ventilador de techo Nos esforzamos continuamente en crear productos de calidad diseñados para mejorar tu hogar Visítanos por Internet para ver nuestra línea completa de productos disponibles a fin de satisfacer tus necesidades de mejoras del hogar Gracias por elegir Hampton Bay Para ver un video instructivo sobre cómo instalar este producto 1 Ir a www homedepot com e introduzca el artículo o el nú...

Page 16: ...de luces debe estar marcado como Adecuado para Uso en Lugares Húmedos Para ensamblar bien consulta las instrucciones adjuntas a los kits de luces e interruptores 9 Este producto es adecuado para usar en lugares húmedos si se instala en un circuito derivado protegido por interruptor diferencial GFCI 10 Antes de la instalación todos los tornillos de fijación tienen que comprobarse y reajustarse dond...

Page 17: ...ay ninguna otra garantía expresa Por este medio Hampton Bay se exime de toda garantía incluyendo pero sin limitarse a aquellas de comercialización e idoneidad para un fin particular en el alcance permitido por la ley La duración de cualquier garantía implícita que no pueda exonerarse se limita al período especificado en la garantía explícita Algunos estados no permiten limitar la duración de la ga...

Page 18: ...asador de soporte 1 DD Pasador de cierre 1 Pieza Descripción Cantidad EE Junta de hule para montaje cerca del techo 1 FF Herrajes adicionales para montaje de aspas 1 GG Interruptor de cadena 1 Preinstalación continuación SE INCLUYEN HERRAJES NOTA Los herrajes no se muestran en tamaño real AA BB CC DD EE FF GG ...

Page 19: ... ventilador 1 Pieza Descripción Cantidad E Caja del interruptor 1 F Cubierta decorativa del collarín del motor 1 G Soporte del aspa brida tornillos preinstalados 5 H Aspa 5 IMPORTANTE Este producto o sus componentes están protegidos por una o más de las siguientes patentes de los EE UU 5 947 436 5 988 580 6 010 110 6 046 416 6 210 117 así como otras patentes pendientes Preinstalación continuación ...

Page 20: ...u soporte tienen que ser aptos para sostener completamente el peso en movimiento del ventilador al menos 35 lb 15 9 kg No uses una caja eléctrica de plástico Las ilustraciones a continuación muestran tres formas distintas de montar la caja eléctrica Si la cubierta toca el tubo bajante retira la tapa inferior decorativa y gira la cubierta 180º antes de fijarla a la placa de montaje Para colgar el v...

Page 21: ...a que encaje en su posición Vuelve a apretar los tornillos de fijación del collarín MM ubicados en la parte superior de la carcasa del motor ventilador D Retira de la cubierta C su aro JJ girándolo hacia la izquierda hasta liberarlo Retira el soporte de montaje A de la cubierta C aflojando los dos tornillos HH ubicados en las ranuras en L Quita y guarda los dos tornillos de la cubierta II en los o...

Page 22: ...an el collarín del motor MM a la parte superior de la carcasa del motor ventilador D Coloca la junta de hule EE sobre los tres tornillos restantes pasa los cables que salen de la parte superior de la carcasa del motor ventilador a través del aro de la cubierta JJ asegúrate de que las aberturas de las ranuras miren hacia arriba y coloca enseguida la cubierta de techo C sobre el collarín en la parte...

Page 23: ...n de cables BB Conecta el cable negro y azul del motor del ventilador al cable negro del hogar usando una tuerca de conexión de cables BB Asegura cada tuerca de conexión de cables BB con cinta de electricista Gira la tuerca de conexión de cables BB hacia arriba y coloca el cableado dentro de la caja eléctrica RR 6 IMPORTANTE Usa las tuercas de conexión de cables BB que vienen con tu ventilador Suj...

Page 24: ...sengancha el ventilador del soporte de montaje deslizante A y alinea las ranuras de cierre de la cubierta del techo C con los dos tornillos HH en el soporte A Empuja hacia arriba para enganchar las ranuras y gira de izquierda a derecha para asegurarlas en su sitio Ajusta inmediatamente con firmeza los dos tornillos de montaje HH Instala los dos tornillos de montaje restantes II en los orificios de...

Page 25: ...s pasos para cada aspa H y su soporte G Fija los ensamblajes de aspa al conjunto motor ventilador D insertando el poste de alineación dentro de la ranura de la parte inferior del motor ajusta los tornillos preinstalados del soporte de aspa TT insertando un destornillador a través del orificio de acceso ZZ Repite este paso para los ensamblajes de aspa restantes girando el motor hasta que se pueda a...

Page 26: ...or deslizable controla la dirección adelante hacia la izquierda o en reversa hacia la derecha Clima cálido Hacia adelante Un flujo de aire descendente surte efecto refrescante Esto te permite fijar el aire acondicionado en configuración más alta sin afectar tu comodidad Clima frío Reversa Un flujo de aire hacia arriba desplaza el aire cálido lejos del techo Esto te permite fijar la unidad de calef...

Page 27: ...ica este nivel seleccionando un punto en el techo sobre la punta de una de las aspas Mide desde un punto en el centro de cada aspa al punto en techo Mide esta distancia Gira el ventilador hasta que la siguiente aspa quede en posición para medir Repite el procedimiento con cada aspa Las desviaciones de la medición no deben pasar de 1 8 plg 0 3 cm Deja que el ventilador funcione por diez minutos Dej...

Page 28: ...tes Antes de devolver a la tienda llama al servicio al cliente de Hampton Bay De lunes a viernes entre 8 00 a m y 7 00 p m Este y los sábados de 9 00 a m a 6 00 p m Este 1 855 HD HAMPTON HAMPTONBAY COM Conserva este manual para uso futuro ...

Reviews: