background image

2

Table of Contents ................................................................ 2

Safety Information ............................................................... 2

Warranty ............................................................................... 3

Pre-Installation .................................................................... 3

Installation ............................................................................ 6

Assembly .............................................................................. 7

Operation ........................................................................... 12

Care and Cleaning ............................................................. 13

Troubleshooting ................................................................. 13

1. 

To reduce the risk of electric shock, ensure the electricity has 
been turned off at the circuit breaker or fuse box before you 
begin.

2. 

All wiring must be in accordance with the National Electrical 
Code ANSI/NFPA 70 and local electrical codes. Electrical 
installation should be performed by a qualified licensed 
electrician.

3. 

The outlet box and support structure must be securely mounted 
and capable of reliably supporting 35 lbs. (15.9 kg). Use only 
UL Listed outlet boxes marked “Acceptable for Fan Support of 
35 lbs. (15.9 kg) or less”.

4. 

The fan must be mounted with a minimum of 7 ft (2.1 m) 
clearance from the trailing edge of the blades to the floor.

5. 

Do not operate the reversing switch while the fan blades are 
in motion. You must turn the fan off and stop the blades before 
you reverse the blade direction.

6. 

Do not place objects in the path of the blades.

7. 

To avoid personal injury or damage to the fan and other items, 
use caution when working around or cleaning the fan.

8. 

Electrical diagrams are for reference only. Light kits that are 
not packed with the fan must be UL-listed and marked suitable 
for use with the model fan you are installing. Switches must be 
UL General Use Switches. Refer to the instructions packaged 
with the light kits and switches for proper assembly.

9. 

After making electrical connections, spliced conductors should 
be turned upward and pushed carefully up into the outlet box. 
The wires should be spread apart with the grounded conductor 
and the equipment-grounding conductor on one side of the 
outlet box.

10. 

All setscrews must be checked and retightened where 
necessary before installation.

WARNING:

 To reduce the risk of personal injury,

do not bend the blade brackets (also referred to as

flanges) during assembly or after installation. Do 

not insert objects in the path of the blades.

WARNING:

 To avoid possible electrical shock,

turn the electricity off at the main fuse box before

wiring. If you feel you do not have enough electrical

wiring knowledge or experience, contact a licensed 

electrician.

WARNING:

 Electrical diagrams are for reference

only. Optional use of any light kit shall be UL-listed

and marked suitable for use with this fan.

Safety Information

Table of Contents

CAUTION:

 To reduce the risk of personal injury,

use only the screws provided with the outlet box.

READ AND SAVE THESE INSTRUCTIONS.

CAUTION:

 Changes or modifications not expressly 

approved by the party responsible for compliance 

could void the user’s authority to operate the 

equipment.

CAUTION:

 Do NOT use this fan with a dimmer 

switch or wall control. Using a dimmer switch or 

wall control will damage the fan.

Summary of Contents for COMFORT BREEZE 68131

Page 1: ...the outlet box 13 Do not mix old and new batteries 14 Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries NOTE The ceiling fan must be set at HIGH speed and light kit i...

Page 2: ...pton Bay through the purchase of this ceiling fan We strive to continually create quality products designed to enhance your home Visit us online to see our full line of products available for your hom...

Page 3: ...you are installing Switches must be UL General Use Switches Refer to the instructions packaged with the light kits and switches for proper assembly 9 After making electrical connections spliced condu...

Page 4: ...sories is not covered by this warranty Because of varying climatic conditions this warranty does not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass f...

Page 5: ...Part Description Quantity AA Pull chain 2 BB Plastic wire connector 3 CC Hanging pin 1 DD Locking pin 1 Pre Installation continued HARDWARE INCLUDED NOTE Hardware not shown to actual size AA CC BB DD...

Page 6: ...ownrod assembly 1 E Fan motor assembly 1 F Light kit fitter assembly 1 G Shatter resistant shade 1 Part Description Quantity H Blade 5 I Blade arm 5 IMPORTANT This product and or components are govern...

Page 7: ...se the appropriate fasteners and materials The outlet box and its bracing must be able to fully support the weight of the moving fan at least 35 lbs Do not use a plastic outlet box The illustrations b...

Page 8: ...the mounting bracket A and turn the canopy counterclockwise to remove the mounting bracket A from the canopy B Assembling the fan Loosen but do not remove the 2 setscrews ZZ on the collar on top of t...

Page 9: ...e outlet box Securely tighten the two mounting screws JJ Carefully lift the fan motor assembly E up to the slide on mounting bracket A Seat the hanger ball portion of the ball downrod assembly D in th...

Page 10: ...larger than 12 gauge house wiring or more than one house wire to connect to the fan wiring consult an electrician for the proper size wire nuts to use Please refer to remote installation instructions...

Page 11: ...screws FF and alignment post EE in the mounting bracket A Push up the canopy B and turn clockwise until the alignment post EE engages to the round hole and the screws FF engage to the key slots Firml...

Page 12: ...he top of the blade brackets I Hold the blade H close to the blade bracket I and press the blade H down firmly Ensure the key slot holes are properly seated on the blade arm posts While still holding...

Page 13: ...ur air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off of the ceiling This allows you to set your heating unit on a lower setti...

Page 14: ...n wobbles Check that all blade and blade arm screws are secure Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of o...

Page 15: ...or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different fro...