background image

40

 | 

Hampton® H15-10 Direct Vent Freestanding Gas Stove

 | 

40

operating instructions

COPY OF THE LIGHTING PLATE INSTRUCTIONS 

919-535

A)   

This appliance is equipped with an ignition device which automatically lights the pilot. 

     Do not try to light the pilot by hand.

B)  BEFORE OPERATING

 smell all around the appliance area for gas. Be sure to smell next to the fl oor 

     because some gas is heavier than air and will settle on the fl oor.
       

WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electric switch, do  not use any phone in your building.

-  Immediately call your gas supplier from a neighbours phone. Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fi re department.

C)   

Do not use this appliance if any part has been under water.  Immediately call a qualifi ed service 

      technician to inspect the appliance and replace any part of the control system and any 

       gas control which has been underwater.

A)  

Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. 

       Ne tentez pas d’allumer la veilleuse manuellement. 

B)   AVANT DE FAIRE FONCTIONNER

, renifl ez tout autour de l’appareil pour déceler une odeur 

      de gaz.  Renifl ez près du plancher, car certains gaz sont pluslourds que l’air et peuvent        

          

          

      s’accumuler au niveau du sol.

       

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

    • Ne pas tenter d’allumer d’appareil

    • Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le 

      bâtiment.

    • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les  

      instructions du fournisseur.

    • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies

C)   

N’utilisez pas cet appareil s’il a été plongé dansl’eau, même partiellement. Faites inspecter  l’appareil par un tech-

nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.

DO NOT REMOVE THIS INSTRUCTION PLATE

TO TURN OFF GAS APPLIANCE

This appliance must be installed in accordance with local codes, if any;

if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or

Natural Gas and Propane Installation Codes, CSA B149.1.

CAUTION:  Hot while in operation. Do not touch. Severe Burns may result. Due to high surface 

temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable 

vapors  away.  Keep  burner  and  control  compartment  clean.  See  installation  and  operating 

instructions accompanying appliance.

WARNING:  If  you  do  not  follow  these  instructions  exactly,  a  fire  or  explosion  may  result 

causing property damage, personal injury or loss of life. Improper installation, adjustment, 

alteration, service or maintenance can cause injury or property damage. Refer to the owner’s 

information manual provided with this appliance. For assistance or additional information 

consult a qualified installer, service agency or gas supplier.

AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice 

risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou 

la mort.

Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer 

des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de 

l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-

taires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.

1) Ensure the Main switch is in the ON position and/or the battery holder switch is in the Remote position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be 

heard from the receiver. 

3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.

4)  The unit will turn on.

Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi ca-

tion) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a 

second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the 

second attempt the board will go into lock out.

The system will need to be reset as follows (after going into lock out mode):

 

a)   Wait 5 minutes - turn the system off by  pressing the ON/OFF button on the remote.

 

b)   After approximately 2 seconds press the ON/OFF button again.

 

c)  Unit will repeat step 2.

1) S’assurer que l’interrupteur principal est en position ON et/ou que l’interrupteur du support de piles est en 

position télécommande2)  Appuyer sur la touche ON/OFF de la télécommande et relâcher. Un bip sonore se 

fera entendre depuis le récepteur

3) Après environ 4 secondes, le système d'allumage des étincelles pendant 60 secondes pour allumer le 

brûleur principal.

4)  Les fl ammes s’allumeront.

Remarque : Au premier allumage, le système tente d’allumer les fl ammes pendant 60 secondes. Si l’essai 

est infructueux, le système fait une pause de 35 secondes. C’est ce qu'on appelle l'étape de rectifi cation. 

Ce délai écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60 

secondes. Si les fl ammes ne s’allument toujours pas, le système se met en mode verrouillage.

 

 Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :

                 a)   Attendre 5 minutes et éteindre l’appareil en appuyant sur la touche ON/OFF de la télécom-

mande.

                 b)   Attendre 2 secondes et appuyer encore une fois sur la touche ON/OFF.                 

 

c) L'unité répétera l'étape 2.

1) 

Press the ON/OFF button on the remote.

2) 

If service is to be performed–you must disconnect power and shut off gas to the unit.

1)

 

Appuyer sur la touche ON/OFF de la télécommande.

2) 

 Si le service est effectuée–vous devez débrancher l'alimentation et coupez le gaz à l'unité.

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Summary of Contents for H15-NG10

Page 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Page 2: ...d appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H15 10 has been approved by Warnock Hersey Intertek for both safet...

Page 3: ...ensions with vertical vent 5 Installation Important Message 8 Specifications 8 Mobile Manufactured Homes After First Sale 8 Before You Start 8 General Safety Information 9 Installation Checklist 9 Cle...

Page 4: ...RIZONTAL VENT 22 7 8 19 3 8 24 11 16 20 11 16 17 13 16 19 1 8 14 1 4 13 5 8 21 1 4 19 1 8 525mm 451mm 485mm 540mm 626mm 581mm 492mm 345mm 485mm 361mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL...

Page 5: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 5 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...

Page 6: ...ements minimaux aux mat riaux combustibles Serial No No de s rie 919 447a This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 o...

Page 7: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 8: ...make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE...

Page 9: ...ssageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpas...

Page 10: ...nce is set as indicated in one of the figures but the connector is too close move the stove until the correct clearance to the connector is obtained This appliance may be installed only with the clear...

Page 11: ...as shown On either side of the unit there will be slits located on the body of the stove Slide the fan up into the slits until the mounting holes line up with the holes locatedonthefanassembly Secure...

Page 12: ...tches securing glass door and remove door 1 Open the front panel and remove the cover plate by removing two screws 6 To reinstall reverse steps 3 Remove 2 bolts and lift off cast front place front car...

Page 13: ...ts products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room...

Page 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air i...

Page 15: ...stable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 B...

Page 16: ...N A N A N A N A N A TM 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB S...

Page 17: ...Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of...

Page 18: ...et with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 fe...

Page 19: ...ote min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverti...

Page 20: ...tibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical...

Page 21: ...m flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However...

Page 22: ...pipe to length Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats...

Page 23: ...hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex...

Page 24: ...6 5 8 Dia x 18 Black Pipe 1 4 Dia x 18 Aluminum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mil...

Page 25: ...stible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks windows soffits gas regulators air supply inlets and public walkways as specified inthe ExteriorVe...

Page 26: ...inch rise for every 1 foot of run towards the ter mination Neverallowtheventtorundownward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal...

Page 27: ...ly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Diagram 5 c Before connecting...

Page 28: ...is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments Note If an offset is necessary in the attic toavoidobstructions itisimporta...

Page 29: ...lot Ignition atalltimes Thiswillavoidnuisance pilot outages during operation of this appli ance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the dista...

Page 30: ...imney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the sup...

Page 31: ...specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do...

Page 32: ...he pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the el...

Page 33: ...Center Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light a...

Page 34: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Page 35: ...nit may be operated by a back up battery system 1 Open the right when facing front of appliance access panel by removing 1 screw 2 Install 4AA batteries into the battery holder Note Remove the batteri...

Page 36: ...Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do...

Page 37: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Page 38: ...lipping the main ON OFF switch located behindthefrontcoverplate totheOFFposition IMPORTANT The remote control system supplied with this appliance has several options for starting operatingtheappliance...

Page 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Page 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Page 41: ...the thermocouple and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contactyourHampton dealerforfurther instructions Nev...

Page 42: ...ch as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the log...

Page 43: ...ve 2 bolts and lift off cast front place front carefully on a soft surface 1 Turn off stove and allow to return to room temperature 2 Shut off electrical supply 3 Lift off cast top and place on a soft...

Page 44: ...two 2 switch wires from valve 5 Lift off the Cast Top and remove the Cast Front and glass door see detailed instruction in this manual 6 Carefully move light bracket out of the way Screws 7 Carefully...

Page 45: ...e Comes With Legs 2 Per Side Sea side Sand W801015 Touch Up Paint Brown 938 317 Touch Up Paint Seaside Sand 9 382 515 Rear Panel Assembly 11 382 516 Valve Cover Assembly 12 382 005 Safety Screen Assy...

Page 46: ...rgrated Fireplace Control Proflame 11 584 306 911 175 Hand Held Remote Control GTMFL 0 584 042 911 179 ASM 120 Volt Power Cord Assembly 911 173 Valve Remote Wiring Harness 584 924 911 177 4 Position W...

Page 47: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 47 47 notes...

Page 48: ...dule Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware...

Page 49: ...ages downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels...

Page 50: ...nal legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the ev...

Page 51: ...below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Pro...

Page 52: ......

Page 53: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 53 53 notes...

Page 54: ...54 Hampton H15 10 Direct Vent Freestanding Gas Stove 54 notes...

Page 55: ......

Page 56: ...e Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Pho...

Reviews: