Hampton® H15-10 Direct Vent Freestanding Gas Stove

  |     

7

7

requirements

5.08: 

Modifications to NFPA-54, Chapter 10

(2) Revise 10.8.3 by adding the following additional requirements: 

(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for 

residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than 

seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall 

be satisfied:  

1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled 

equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is 

installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery 

operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure 

served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of 

qualified licensed professionals for the installation of hard wired carbon monoxide detectors 

a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon 

monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. 

b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of 

thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon 

monoxide detector with an alarm shall be installed. 

2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions 

shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.  

3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 

(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The 

sign shall read, in print size no less than one-half (1/2) inch in size, 

"GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL 

OBSTRUCTIONS". 

4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation 

unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 

5.08(2)(a)1 through 4.  

(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:  

1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by 

the Board; and  

2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or 

structure used in whole or in part for residential purposes.  

(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product 

Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the 

instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 

1. Detailed instructions for the installation of the venting system design or the venting system components; and 

2. A complete parts list for the venting system design or venting system.  

(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a 

Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies 

"special venting systems", the following requirements shall be satisfied by the manufacturer: 

1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and  

2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and 

detailed installation instructions.  

(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, 

all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of 

the installation.  

MA Code - CO Detector

(for the State of Massachusetts only)

Summary of Contents for H15-NG10

Page 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Page 2: ...d appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model H15 10 has been approved by Warnock Hersey Intertek for both safet...

Page 3: ...ensions with vertical vent 5 Installation Important Message 8 Specifications 8 Mobile Manufactured Homes After First Sale 8 Before You Start 8 General Safety Information 9 Installation Checklist 9 Cle...

Page 4: ...RIZONTAL VENT 22 7 8 19 3 8 24 11 16 20 11 16 17 13 16 19 1 8 14 1 4 13 5 8 21 1 4 19 1 8 525mm 451mm 485mm 540mm 626mm 581mm 492mm 345mm 485mm 361mm ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL...

Page 5: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 5 5 dimensions UNIT DIMENSIONS WITH VERTICAL VENT...

Page 6: ...ements minimaux aux mat riaux combustibles Serial No No de s rie 919 447a This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 o...

Page 7: ...directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT...

Page 8: ...make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE...

Page 9: ...ssageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpas...

Page 10: ...nce is set as indicated in one of the figures but the connector is too close move the stove until the correct clearance to the connector is obtained This appliance may be installed only with the clear...

Page 11: ...as shown On either side of the unit there will be slits located on the body of the stove Slide the fan up into the slits until the mounting holes line up with the holes locatedonthefanassembly Secure...

Page 12: ...tches securing glass door and remove door 1 Open the front panel and remove the cover plate by removing two screws 6 To reinstall reverse steps 3 Remove 2 bolts and lift off cast front place front car...

Page 13: ...ts products of combustion to the outside while the outer pipe draws outside combustion air into the combustion chambertherebyeliminatingtheneedtouseheated room air for combustion and losing warm room...

Page 14: ...of center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air i...

Page 15: ...stable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 B...

Page 16: ...N A N A N A N A N A TM 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB S...

Page 17: ...Vent SelkirkDirect Temp AmeriVent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of...

Page 18: ...et with min of 8 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required With these options maxi mum total pipe length is 30 feet with minimum of 6 fe...

Page 19: ...ote min 1 foot be tween90o elbowsisrequired Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverti...

Page 20: ...tibles May be installed in Manufactured Mobile Homes after first sale Horizontal Terminations for All Venting Systems The shaded areas in the diagram below show all allowable combinations of vertical...

Page 21: ...m flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will accommodate However...

Page 22: ...pipe to length Attachthe 45o elbowtotherigid pipe and ensure that the pipe length when cut with the 45o elbow will seat onto both the starter collar and the 90o elbow Crimpedsectionofrigidpipe seats...

Page 23: ...hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex...

Page 24: ...6 5 8 Dia x 18 Black Pipe 1 4 Dia x 18 Aluminum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 640 530 P Riser Vent Terminal 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mil...

Page 25: ...stible surfaces is 1 1 4 inch Be sure to check the vent termination clearance requirements from decks windows soffits gas regulators air supply inlets and public walkways as specified inthe ExteriorVe...

Page 26: ...inch rise for every 1 foot of run towards the ter mination Neverallowtheventtorundownward This could cause high temperatures and may present the possibility of a fire b The location of the horizontal...

Page 27: ...ly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Diagram 5 c Before connecting...

Page 28: ...is installed under the roofing material and not nailed down until the chimney is installed This allows for small adjustments Note If an offset is necessary in the attic toavoidobstructions itisimporta...

Page 29: ...lot Ignition atalltimes Thiswillavoidnuisance pilot outages during operation of this appli ance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the dista...

Page 30: ...imney in a convenient location as near as possible to the appliance outlet Cut and frame a hole in the roof for the support The sides of this hole must be vertical with 1 1 4 clearance 2 Place the sup...

Page 31: ...specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do...

Page 32: ...he pilot orifice with the allen key and replace with the LP pilot orifice in the kit and replace pilot cap 7 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the el...

Page 33: ...Center Front Log e Embers f Platinum Embers 946 669 supplied with packaged manual Left Front Log Right Front Log 4 Remove Glass front see instructions in manual 3 Remove Cast Front and set the light a...

Page 34: ...of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports 11 Re install the Glass Front Cast Front and Top 8 Take the embers and place on the burner...

Page 35: ...nit may be operated by a back up battery system 1 Open the right when facing front of appliance access panel by removing 1 screw 2 Install 4AA batteries into the battery holder Note Remove the batteri...

Page 36: ...Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do...

Page 37: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 37 37 operating instructions WIRING DIAGRAM WITH THERMOSTAT Thermostat Optional Millivolt...

Page 38: ...lipping the main ON OFF switch located behindthefrontcoverplate totheOFFposition IMPORTANT The remote control system supplied with this appliance has several options for starting operatingtheappliance...

Page 39: ...oard will go into lock out The system will need to be reset as follows a Wait 5 minutes turn the system off by pressing the ON OFF button on the remote b After approximately 2 seconds turn on ON OFF s...

Page 40: ...nsult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas la lettre les instructions dans la pr sente notice risquede d clencher un incendie ou une explosion e...

Page 41: ...the thermocouple and 1 flowing across the rear of the burner it does not have to be touching the burner Note If you have an incorrect flame pattern contactyourHampton dealerforfurther instructions Nev...

Page 42: ...ch as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT Theunitshouldneverbeusedwithbrokenlogs Turn off the gas valve and allow the unit to cool before opening door to carefully remove the log...

Page 43: ...ve 2 bolts and lift off cast front place front carefully on a soft surface 1 Turn off stove and allow to return to room temperature 2 Shut off electrical supply 3 Lift off cast top and place on a soft...

Page 44: ...two 2 switch wires from valve 5 Lift off the Cast Top and remove the Cast Front and glass door see detailed instruction in this manual 6 Carefully move light bracket out of the way Screws 7 Carefully...

Page 45: ...e Comes With Legs 2 Per Side Sea side Sand W801015 Touch Up Paint Brown 938 317 Touch Up Paint Seaside Sand 9 382 515 Rear Panel Assembly 11 382 516 Valve Cover Assembly 12 382 005 Safety Screen Assy...

Page 46: ...rgrated Fireplace Control Proflame 11 584 306 911 175 Hand Held Remote Control GTMFL 0 584 042 911 179 ASM 120 Volt Power Cord Assembly 911 173 Valve Remote Wiring Harness 584 924 911 177 4 Position W...

Page 47: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 47 47 notes...

Page 48: ...dule Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware...

Page 49: ...ages downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels...

Page 50: ...nal legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the ev...

Page 51: ...below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Pro...

Page 52: ......

Page 53: ...Hampton H15 10 Direct Vent Freestanding Gas Stove 53 53 notes...

Page 54: ...54 Hampton H15 10 Direct Vent Freestanding Gas Stove 54 notes...

Page 55: ......

Page 56: ...e Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Pho...

Reviews: