H35E-11 Direct Vent Freestanding Gas Stove
|
27
installation
Offset to Vertical Terminations
Venting Arrangements
Vertical Terminations Systems for
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical and
offset to vertical runs with vertical terminations.
Maximum two 45
o
elbows
.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) Homes after first sale.
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below show
all allowable combinations of vertical runs with
horizontal terminations. Maximum one 90
O
elbow (two 45
o
elbows equal one 90
o
elbow).
All approved caps listed in this manual - may
be used.
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
The venting arrangements diagrammed below,
have a min. of 75% (flue loss) efficiency with Fan
Off, as required for manufactured homes. (Actual
efficiency may be as high as 85%)
May be installed in Manufactured (Mobile)
Homes after first sale.
NOTE: See "Vent Restrictor Position" section for
installation instructions for the Vent Restrictor
Position.