16
Hampton H35 Direct Vent Freestanding Gas Stove
Venting Arrangements - Vertical Terminations
with Co-linear Flex System for both
Residential & Manufactured Homes
into Masonry Fireplaces
The shaded area in the diagram shows the allowable
vertical terminations.
Note: Must remove 4 screws from
stove collar and rotate 180
o
to have collar facing straight
back. Secure into place with 4 screws.
VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to two
3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will accommodate.
However,
keep the flexible liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Straight Vertical Terminations
INSTALLATION
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Alternate Approved Caps
980
Vertical Termination Cap
991
High Wind Cap
923GK 3" Co-linear Adapter with flashing
Vent Restrictors
set at 1-3/4" open
(fully open),
Posiiton "A"