8.
Finishing the Fan
Installation
STANDARD CEILING MOUNTING
1. Align the locking slots of the ceiling canopy
with the two screws in the mounting plate.
Push up to engage the slots and turn clock-
wise to lock in place. Immediately tighten
the two mounting screws firmly.
2. Install the remaining two mounting
screws into the holes in the canopy and
tighten firmly.
3. Install the decorative canopy ring by
aligning the ring’s slots with the screws
in the canopy. Rotate the ring counter-
clockwise to lock in place.
4. You may now proceed to attaching the
fan blades.
CLOSE-TO-CEILING MOUNTING
1. Carefully unhook the fan from the mount-
ing plate and align the locking slots of the
ceiling canopy with the two screws in the
mounting plate. Push up to engage the slots
Attaching the
Fan Blades
1. Attach the blade to the fan motor housing by
inserting the blade into the slot in the side
of the fan motor housing and secure using
the screws provided as shown in Figure 14.
Start a screw into the bracket. Repeat for the
two remaining screws.
2. Tighten each screw securely.
3. Repeat steps 1, 2 & 3 for the remaining
blades.
and turn clockwise to lock in place. Imme-
diately tighten the two mounting screws
firmly.
2. Install the remaining two mounting screws
into the holes in the canopy and tighten
firmly.
3. Install the decorative canopy ring by align-
ing the ring’s slots with the screws in the
canopy. Rotate the ring clockwise to lock in
place.
4. You may now proceed to attaching the fan
blades.
WHEN USING THE STANDARD BALL/DOWNROD
MOUNTING, THE TAB IN THE RING AT THE BOT-
TOM OF THE MOUNTING PLATE MUST REST IN
THE GROOVE OF THE HANGER BALL. FAILURE
TO PROPERLY SEAT THE TAB IN THE GROOVE
COULD CAUSE DAMAGE TO WIRING.
LOCKING SLOTS OF CEILING CANOPY ARE
PROVIDED ONLY AS AN AID TO MOUNTING. DO
NOT LEAVE FAN ASSEMBLY UNATTENDED UN-
TIL ALL FOUR CANOPY SCREWS ARE ENGAGED
AND FIRMLY TIGHTENED.
Blade
Screws
Slot Cut-Off for
Blade lnsert
Fan Motor Housing
Figure 14
BLADE BALANCING
All blades are grouped by weight. Because nat-
ural woods vary in density, the fan may wobble
even though the blades are weight matched. The
following procedure should correct most fan
wobble. Check after each step.
1. Check that all blade and blade bracket
screws are secure.
2. Most fan wobble problems are caused when
blade levels are unequal. Check this level
by selecting a point on the ceiling above
the tip of one of the blades. Measure from
a point on the center of each blade to the
point on the ceiling. Measure this distance
as shown in Figure 15. Rotate the fan until
the next blade is positioned for measure-