background image

  

To hang your fan where there is an existing fixture but no ceiling 
joist, you may need an installation hanger bar (OO) (not included) 
as shown above.

If your ceiling fan does not have an existing UL-listed mounting 
box, then install one using the following instructions:

      

Disconnect the power by removing the fuses or turning off 
the circuit breakers.

      

Secure the outlet box (NN) (not included) directly to the 
building structure. Use appropriate fasteners and materials 
(not included). The outlet box and its bracing must be able 
to fully support the weight of the moving fan (at least 35 
lbs.). Do not use a plastic outlet box.

The illustrations below show three different ways to mount the 
outlet box (NN) (not included).

NN

NN

OO

NN

NN

A

Installation 

MOUNTING OPTIONS

MOUNTING OPTIONS

 

WARNING:

 

To reduce the risk of fire, electric shock, or 

personal injury, mount the fan to an outlet box marked 
acceptable for fan support using the screws provided with the 
outlet box. An outlet box commonly used for the support of 
lighting fixtures may not be acceptable for fan support and 
may need to be replaced. If in doubt, consult a qualified 
electrician.

NOTE:

 

You may need a longer downrod to maintain proper 

blade clearance when installing on a steep, sloped ceiling. 
The maximum angle allowable is 18° away from horizontal. If 
the canopy (B) touches the hanger ball/downrod assembly 
(D), then remove the decorative canopy bottom cover (C) and 
turn the canopy (B) 180° before attaching the canopy (B) to 
the mounting bracket (A).

8

Summary of Contents for YG269AP-MWH

Page 1: ...FAN Item 1003 021 039 Model YG269AP MWH 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday Questions problems missing parts Before returning to the store call Home Depot Customer Service 1 877 52...

Page 2: ...ructions Installation Assembly Standard Ceiling Mounting Close to Ceiling Mounting Hanging the Fan Attaching the Fan Blades Installing the Light Kit 2 3 4 4 4 4 5 6 7 8 9 9 10 11 14 16 Operation Pull...

Page 3: ...an 3 The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs 15 9 kg or less Use only UL listed outlet boxes marked FOR FAN SUPPORT 4 The f...

Page 4: ...not cover any changes in brass finish including rusting pitting corroding tarnishing or peeling Brass finishes of this type give their longest useful life when protected from varying weather condition...

Page 5: ...llar setscrew preassembled Collar mounting screw with lock washer preassembled Light kit mounting screw preassembled Light holder thumbscrew preassembled 9 Watt LED bulb not to scale Pull chain and fo...

Page 6: ...ade Part A B C D E Quantity 1 1 1 1 1 Quantity 5 5 1 1 Description Mounting bracket preassembled Canopy Canopy bottom cover preassembled Hanger ball downrod assembly Fan motor assembly PACKAGE CONTENT...

Page 7: ...he standard downrod installation the distance from the ceiling to the bottom of the fan blades will be approximately 12 in The close to ceiling installation reduces the distance from the ceiling to th...

Page 8: ...ree different ways to mount the outlet box NN not included NN NN OO NN NN A Installation MOUNTING OPTIONS MOUNTING OPTIONS WARNING To reduce the risk of fire electric shock or personal injury mount th...

Page 9: ...he clevis pin EE against the wiring inside the hanger ball downrod assembly D Insert the cotter pin FF through the hole near the end of the clevis pin EE until it snaps into the locked position Tighte...

Page 10: ...mounting screws with lock washers HH every other one from the collar on top of the fan motor assembly E Make sure the slot openings of the canopy B are on top and then proceed to place the canopy B o...

Page 11: ...g system marked acceptable for fan support and use the mounting screws provided with the outlet box WARNING The tab in the ring must rest in the groove of the hanger ball D Failure to properly seat th...

Page 12: ...o your household wiring Use the plastic wire nuts AA with your fan Secure the plastic wire nuts AA with electrical tape Make sure there are no loose strands or connections Connect the ground conductor...

Page 13: ...ned WARNING Make sure the tab on the mounting bracket A properly sits in the groove in the hanger ball D before attaching the canopy B to the mounting bracket A by turning the canopy B until it drops...

Page 14: ...to blade arms G using the three screws with fiber washers provided with the blade attachment hardware CC Start a screw with fiber washer CC into the blade arm G but do not tighten Repeat for the two...

Page 15: ...ade arms G while installing balancing the blades F or cleaning the fan Do no insert foreign objects between rotating fan blades F Align motor holes to blade arms G and secure with screws DD provided t...

Page 16: ...th the three light kit mounting screws II provided Be sure to tighten all screws CAUTION Before starting the installation disconnect the power by turning off the circuit breaker or removing the fuse a...

Page 17: ...sing cover RR from the light kit H You can keep the light kit H for future use Attach the plastic plug MM to the switch housing cover RR Install the switch housing cover RR to the switch housing QQ wi...

Page 18: ...ceiling height and number of fans To turn the light kit ON or OFF pull the chain that is attached to the light kit H REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The re...

Page 19: ...before you attempt any repairs Refer to the section Making the Electrical Connections on page 12 Problem Problem Solution Solution Check the main and branch circuit fuses or breakers Check the line wi...

Page 20: ...ing above the tip of one of the blades then select any fan blade and measure from the center of the selected blade to the point on the ceiling Rotate the fan until the next blade is positioned and rep...

Page 21: ...anopy mounting screw with lock washer preassembled Blade attachment screw and fiber washer Blade arm screw and lock washer preassembled Clevis pin preassembled Cotter pin preassembled Collar setscrew...

Page 22: ...3 Retain this manual for future use YG269AP001 A 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday Questions problems missing parts Before returning to the store call Home Depot Customer Service...

Reviews: