LT-S-(L) Technical manual
10.2.3
Check valve
Hanbell configured for the LT series models of the exhaust valve is horizontal.
When the compressor is stopped, the teflon valve will automatically close the valve
by the drive of the internal spring to block the reverse flow of the high-pressure
airflow, thus greatly reducing the compressor reversal time and protecting the
compressor.
1
)
Economizer check valve (Horizontal type)
Figure 10-4.Economizer check valve
Size
UOM: mm
A
B
C
D
E
F
G
H
I
2”
102
6
53
69
91
65
90
85
5
2 1/2
122
6
69
89
111
85
110
97
5
3
138
6
80
99
121
95
120
108
5
4
163
6
96
124
146
120
145
123
5