4.4.5 Connection notice
1. Check the power supply characteristics in line with the nameplate. The power cable must be made
of copper.
2. It is not allowed to change the shape and dimension of cable box.
3. The power bolts are made of brass, which cannot sustain the weight of high voltage cables. External
cable shelves or tension-ease devices to support the high voltage cables must be applied. HANBELL
does not provide wiring terminals.
4. When tightening the terminals of power bolts, use torque wrench with the torque lower than
700kgf-cm (5/8” & 9/16” copper nut).
5. Cable wiring and construction inspection rules must follow local electrical regulations.
6. The insulation material of the main power and control cables should be screen effective to avoid
signal interferes, and maintain proper distance in between cables during installation.
4.5 MCC (Maximum Continuous Current) of motor
Model
Voltage(V)
(kW)
MCC (A)
RTM-090
380
310
597