5 - 2
3800i/3800r User’s Guide
inside back cover to program the scanner for your terminal ID (you must
enter 3 digits). For example, scan 0 0 3 for an AT wedge.
Note: The wildcard for all terminal types is 099.
Step 4. Code I.D.
In the
Appendix A
, find the symbology to which you want to apply the
data format. Locate the Hex value for that symbology and scan the 2
digit hex value from the
Programming Chart
inside the back cover of
this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
Program-
ming Chart
inside the back cover of this manual. (Note: 50 characters is
entered as 0050. 9999 is a universal number, indicating all lengths.)
Step 6. Editor Commands
Refer to the Format Editor Commands Chart (
page 5-2
). Scan the sym-
bols that represent the command you want to enter. 94 alphanumeric
characters may be entered for each symbology data format.
Step 7. Scan Save from the
Programming Chart
inside the back cover of this
manual to save your entries.
Other Programming Selections
•
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan 0 from the
Programming Chart
inside the back cover of
this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending
on the alternate format you are clearing. Scan the Terminal Type (refer to the
Supported Terminals Chart on
page 2-2
), Code I.D. (refer to the
Symbology
Chart
on page A-1), and the bar code data length for the specific data format
that you want to delete. All other formats remain unaffected.
•
Save from the
Programming Chart
inside the back cover of this manual
This exits, saving any Data Format changes.
•
Discard from the
Programming Chart
inside the back cover of this manual
This exits without saving any Data Format changes.
Data Format Editor Commands
Send Commands
F1 Send all characters followed by “xx” key or function code, starting from cur-
rent cursor position.
Syntax = F1xx (xx stands for the hex value for an
ASCII code, see
ASCII Conversion Chart (Code Page 1252)
on page A-2.)
F2 Send “nn” characters followed by “xx” key or function code, starting from
current cursor position.
Syntax = F2nnxx (nn stands for the numeric value
Summary of Contents for IMAGETEAM 3800i
Page 6: ......
Page 18: ...1 4 3800i 3800r User s Guide 3800i 3800r Scanner Identification...
Page 19: ...3800i 3800r User s Guide 1 5 3800i Scanner with aimer beam option Identification...
Page 30: ...1 16 3800i 3800r User s Guide...
Page 70: ...5 6 3800i 3800r User s Guide...
Page 76: ...6 6 3800i 3800r User s Guide...
Page 112: ...7 36 3800i 3800r User s Guide...
Page 140: ...11 18 3800i 3800r User s Guide...
Page 150: ...12 10 3800i 3800r User s Guide...
Page 158: ...14 4 3800i 3800r User s Guide...
Page 163: ......
Page 164: ......