3 - 37
padPassThroughResetCodes
This command resets the pass through “ON” and “OFF” codes to the factory defaults. The default codes are two bytes in
length. The default “ON” code is AA 55 in hexadecimal (170 85 in decimal). The default “OFF” code is 55 AA in hexadecimal
(85 170 in decimal). After using this command you must use these default values when enabling or disabling pass through
for that pad.
Note: You cannot use this command to reset the codes of a pad that is currently in pass through mode. If a pad is in pass
through mode it will ignore this command and send it to its pass through port.
See
padPassThroughSetOnCode
and
padPassThroughSetOffCode
for more information on using the correct code for
turning on pass through mode.
Syntax
WORD padPassThroughResetCodes(
void
)
Returns
Returns non-zero if successful, zero otherwise.
See Also
padPassThroughOff, padPassThroughSetOffCode, padPassThroughSetOnCode, padPassThroughOn
padPassThroughSetOffCode
This command sets the pass through “OFF” code of a pad. The code can be from 1 to 4 bytes in length. After setting the
“OFF” code you must use the same “OFF” code when disabling pass through mode for that pad or you will not be able to
disable pass through mode for that pad (see
padPassThroughOff
). You can have a chain of pads connected in series using
the pass through ports of each pad. Giving each pad a unique “OFF” code allows you to selectively disable pass through
mode for a specific pad. If any two or more pads have the same “OFF” code then
padPassThroughOff
disables the first
pad with that “OFF” code in the chain.
Note: You cannot use this command to set the “OFF” code of a pad that is currently in pass through mode. If a pad is in pass
through mode it will ignore this command and send it to its pass through port.
Syntax
WORD padPassThroughSetOffCode(
char *code,
WORD codeLength
)
Parameter
Description
code
A buffer containing the binary code used to turn off pass through mode
codeLength
The length of the binary pass through code in bytes
Returns
Returns non-zero if successful, zero otherwise.
See Also
padPassThroughOff, padPassThroughResetCodes, padPassThroughSetOnCode, padPassThroughOn
padPassThroughSetOnCode
This command sets the pass through “ON” code of a pad. The code can be from 1 to 4 bytes in length. After setting the
“ON” code you must use the same “ON” code when enabling pass through mode for that pad or you will not be able to enable
pass through mode for that pad (see
padPassThroughOn
). If you have more than two pads connected together in a series
using the pass through ports it is not nessesary for each pad to have a unique “ON” code, however, it is very useful for each
pad to have a unique “OFF” code (see
padPassThroughSetOffCode
).
Summary of Contents for PadCom TT1500