3 - 10
Quick Check® 600/800 Series User’s Guide
Consider the symbol grade as the average resulting from scans you take from all
over the symbol. The ISO/IEC standard requires you to obtain ten scans of each
symbol.
For example, you might sample the symbol at ten different paths in the symbol
— four in the upper portion, two in the middle and four in the lower portion.
Multiple scans of the same symbol across different scan paths take advantage
of the vertical redundancy of bar codes and give you a more accurate value of
the symbol’s overall print quality.
♦
To change the test criteria:
1. Display the menu that begins with Print Results (press
POWER
and then
SELECT
).
2. Set the cursor on the asterisk next to Change Settings and then press
SELECT
. A menu that begins with Specifications appears.
3. Set the cursor on the asterisk next to Test Criteria and then press
SELECT
.
A menu that begins with Passing appears.
•
To change the pass/fail criteria
, set the cursor on the asterisk next to
the term Passing and then press
SELECT
or
→
. The cursor moves to
the right of Passing. Press
↑
and
↓
until the grade (Trad’l, ISO/IEC
“A,” ISO/IEC “B,” ISO/IEC “C,” ISO/IEC “D,”) you want appears. To
save the selection, press
SELECT
,
POWER
or
←
. The cursor moves
back to the asterisk next to Passing.
•
To change the Decodability
, set the cursor on the asterisk next to
Decodability and then press
SELECT
or
→
. The setting changes
between ISO/IEC and Avg.
•
To change the Grades
, set the cursor on the asterisk next to Grades
and then press
SELECT
or
→
. The setting changes between Letters
and Numbers.
•
To change the number of scans used to determine the final ISO/
IEC Symbol Grade
, set the cursor on the asterisk next to #Scans/
Symbol and then press
SELECT
or
→
. The cursor moves to the right
of the terms #Scans/Symbol. Press
↑
and
↓
until the numeric value
you want (1 through 10, 12, 15, 20, 30, 50, 100 or Var) appears. To
save the selection, press
SELECT
or
←
. The cursor moves back to
the asterisk next to #Scans/Symbol.
When you exit any menu (press
POWER
), all the displayed parameter
choices are saved.
4.
To return to the previous menu
, press
POWER
.
To scan a symbol
, set the wand on the symbol’s quiet zone.
Changing the Scanning Options
The scanning options apply to the general operation of the Quick Check 600/800
Verifier. You can change the following options:
Summary of Contents for Quick Check 600 Series
Page 1: ... User s Guide Quick Check 600 800 Series Bar Code Verifiers ...
Page 22: ...1 16 Quick Check 600 800 Series User s Guide ...
Page 44: ...3 20 Quick Check 600 800 Series User s Guide ...
Page 47: ...Quick Check 600 800 Series User s Guide 4 3 Determining the ISO IEC Symbol Grade ...
Page 48: ...4 4 Quick Check 600 800 Series User s Guide Determining the ISO IEC Symbol Grade continued ...
Page 74: ...5 12 Quick Check 600 800 Series User s Guide ...
Page 88: ...7 6 Quick Check 600 800 Series User s Guide ...
Page 103: ...Quick Check 600 800 Series User s Guide 10 1 10 Flow Charts ...
Page 104: ...10 2 Quick Check 600 800 Series User s Guide ...
Page 105: ...Quick Check 600 800 Series User s Guide 10 3 ...
Page 106: ...10 4 Quick Check 600 800 Series User s Guide ...
Page 107: ...Quick Check 600 800 Series User s Guide 10 5 ...
Page 108: ...10 6 Quick Check 600 800 Series User s Guide ...
Page 109: ...Quick Check 600 800 Series User s Guide 11 1 11 SSTR Codes ...
Page 110: ...11 2 Quick Check 600 800 Series User s Guide ...
Page 111: ...Quick Check 600 800 Series User s Guide 12 1 12 Special Codes ...
Page 112: ...12 2 Quick Check 600 800 Series User s Guide ...
Page 114: ...13 2 Quick Check 600 800 Series User s Guide ...
Page 119: ......