Quick Check® SV Series User’s Guide
6 - 15
The transmission is available in any output interface mode that includes a no
read condition. The transmission data format enabled (~OS#) does not affect the
format of the No Read transmission.
~LS##
Set minimum number of scans for valid read
## = 02 – 99
This command sets the minimum number of times a full decode must be
achieved on a symbol in order to be a valid read. The system acts slightly
differently, depending on what operation mode is set – ~HO1 or ~HO2.
With ~HO1 enabled, if the minimum number of full decodes is not accomplished,
a No Read condition is set, even though the bar code is read, analyzed and
reported. The report includes a No read status indication. With ~HO2 enabled,
if the minimum number of full decodes is not accomplished, the code is not
recognized nor reported. This essentially creates a No Read condition when a
sync input is being received.
When used in conjunction with the ~LDxx command, the ~LS## command can
create a powerful area check of a symbol.
~LT#
Sync Input Source
~LV##
Output Interface Mode
## = 00 - 99:
This command sets the output interface mode of the unit. Modes have fixed port
activation logic defined by specific applications. Some activation parameters are
programmable. Custom modes are available – contact Hand Held Products
Technical Support. Modes included in standard SV Series are described in the
Output Interface Modes Descriptions Section. Example: ~LV01 sets mode 01.
~LX#
Sync Type
0
Isolated Input (Pins 1(+), 2(-))
1
TTL Input (Pin 4)
0
Envelope sync
1
Edge sync