6 - 22
Quick Check® SV Series User’s Guide
Except for the sync indicator, if a bit is clear, the inactive state of the port is OFF.
For example:
~PR0210 = sync indicator goes “ON” when a sync is detected and Port 1 goes
“OFF” when activated. All other ports go “ON” when activated.
~Px
Save the new port configuration by writing it onto the flash.
~PY
Cancel the current port setup (restore the old Port configuration by getting the old
values from the flash).
~PZpii
List the parameter action. (Parameter actions are set by the ~PP command.)
Port- p
ID- ii
Indicator
Digit Value
Power Indicator
0x0001
Read LED
0x0002
LED1
0x0004
LED2
0x0008
Port 1
0x0010
Port 2
0x0020
Port 3
0x0040
Port 4
0x0080
Port 5
0x0100
*Sync Indicator
0x0200
*Inverted logic