Quick Check® SV Series User’s Guide
6 - 25
Mode 01 (~LV01)
Mode 01 I/O operation
1. System will operate in Edge Sync or Envelope sync mode (~LX#)
2. Sync polarity programmable (~LP#)
3. Use ~PR0210 for proper port initialization.
4. Port 1 will go active OFF (no current) on an error condition.
5. Port 2 will go active ON (sink current) on an error condition.
6. Pushing the reset button or power re-cycle will place Ports 1 and 2 in their
inactive states and reset the # codes per sync counter.
7. Error conditions available are:
a. Partial Read (Programmable, ~LQ#, ~Lp#)
b. % decode (Programmable, ~LD##)
c. Bad Quiet Zone (~PB816xxx100)
d. ANSI Defects grade (Programmable, ~PB806xxx000)
e. ANSI Decodability (Programmable, ~PB802xxx100)
f.
Symbol Contrast grade (Programmable, ~PB804xxx100)
g. Overall ANSI Grade (Programmable, ~LAxx)
h. No Read (if sync is received)
i.
Number of codes per sync programmable (~LN##, ~LZ##)
Mode 01 LED Operation
1. LED1 will turn on if Outputs 1 and 2 go active due to ANSI, contrast, or quiet
zone failure
2. LED2 will turn on if Outputs 1 and 2 go active due to a partial or no read
condition
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important to Mode 01
This system is operating in a “mode” rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.