Quick Check® SV Series User’s Guide
6 - 31
e. ANSI Decodability grade programmable (~PB802xxx100)
f.
Symbol Contrast grade programmable (~PB804xxx100)
g. Overall ANSI Grade (Programmable, ~LAxx)
h. No Read (if edge sync is received)
i.
Number of codes per sync programmable (~LN##, ~LZ##)
Mode 12 LED Operation
1. LED1 will turn on if Ports 1-4 go active due to ANSI, contrast, or quiet zone
failure
2. LED2 will turn on if Ports 1-4 go active due to a partial or no read condition
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important to Mode 12
This system is operating in a “mode” rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.
~LV12
This command sets this mode of operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
Summary of Contents for SV series