6 - 34
Quick Check® SV Series User’s Guide
j.
X dimension (Programmable ~PB811xxxyyy)
Mode 16 LED Operation
1. LED1 will turn on during the time a Port goes active due to any bar code
quality or dimensional error.
2. LED2 will turn on during the time a Port goes active due to a partial or no
read condition
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important to Mode 16
This system is operating in a “mode” rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.
~LV16
This command sets the proper mode for this operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
~PP801xxx
This command sets the “active” time for the port pulses. The value “xxx” sets the
time in .1 second intervals. Any value greater than 100 (10 seconds) creates a
latching output.
~LDxx
This command sets the % decode threshold for a passing condition. If analyzing
poorly printed symbols, it is recommended that partial decodes be enabled at the
decoder level when this command is enabled.
xx = failure threshold. Example ~LD75: if 74 % or less of scans on a code were
not fully decoded, this sets a failure for this parameter.
Summary of Contents for SV series
Page 1: ... User s Guide Quick Check SV Series Bar Code Scanner Verifier ...
Page 8: ...iv ...
Page 16: ...2 6 Quick Check SV Series User s Guide ...
Page 22: ...3 6 Quick Check SV Series User s Guide ...
Page 98: ...8 6 Quick Check SV Series User s Guide ...
Page 103: ......