Quick Check® SV Series User’s Guide
6 - 41
5. Flashing indication will override a solid on indication if both types of error
conditions occur.
Note: Both LEDs can be on in cases where multiple bar codes are analyzed in
a sync period.
SV Commands Important to this System
This system is operating in a “mode” rather than fully programmable logic. The
port activation parameters are programmable via the ~PB8 rather than ~PB1,
~PB2, etc. for each individual port. Other commands, such as mode commands
are also available. The commands most useful for this system application are
described below.
~LV18
This command sets this mode of operation.
~Lp0
This command turns off all partial decode logic at the decoder level
~Lp1
This command turns on partial decode logic at the decoder level
~LQ1
This command allows partial decodes to activate the output ports
~LQ0
This command disables partial decodes to activate output ports.
~LAxx
This command sets the passing threshold for the Overall ANSI method Symbol
Grade. For example: ~LA28 causes an Overall Symbol Grade of 2.7 or lower
calculated for the code analyzed to set a failure condition for this parameter.
~LDxx
This command sets the % decode threshold for a passing condition. If analyzing
poorly printed symbols, it is recommended that partial decodes be enabled at the
decoder level when this command is enabled.
xx = failure threshold. Example ~LD75: if 74 % or less of scans on a code were
not fully decoded, this sets a failure for this parameter.
~PP801xxx
This command sets the “active” time for the port pulses. The value “xxx” sets the
time in .1 second intervals. Any value greater than 100 (10 seconds) creates a
latching output.