Page 26
HQ
18
Avanté User Manual
Figure 49
Press the “Main” button to return to the “Regulated” or
“Manual” menu screen or the “Back” button to return to
the “More” menu screen.
Motor Speed Sensor Test
The “Speed” Sensor test can help you determine whether
or not there is a problem with the HQ
18
Avanté speed
sensor. Before performing this test, remove the bobbin
case and the top thread. Press the “Start” button and the
machine will begin slowly rotating. The white box will
show a number that should stabilize at 100 if the sensor
is functioning properly. Pressing “Start” again will stop
the machine. (Figure 48)
Press the “Main” button to return to the “Regulated” or
“Manual” menu screen or the “Back” button to return to
the “More” menu screen.
Y Motion Sensor Test
Use the Y Motion Sensor test to verify functionality of
the “Y” stitch regulator encoder (the encoder mounted
to the rear power pod side machine wheel). As you
slowly move the carriage toward and away from you, you
should hear a pulsing “beep” that pulses faster as you
move faster. A solid beep, no beep, or periods of irregu-
lar beeping (with constant motion) indicate a problem
with the “Y” encoder.
The most likely cause of a problem is a stitch regulator
wheel that is not making consistent contact with the
track. Check the spring tension on the sensor assembly
on the machine to assure that it will easily return to the
fully extended (down) position after being compressed.
Also assure that the track is straight with no dips or in-
dentations and that it is clean and free of contamination.
Other causes are an unplugged or damaged cable or pos-
sibly an issue with the main control board. (Figure 49)
Press the “Main” button to return to the “Regulated” or
“Manual” menu screen or the “Back” button to return to
the “More” menu screen.
Keypad Test
The Keypad test allows the user to press any of the four
keys on the front or back handles to verify that the HQ
18
Avanté is reading the buttons as they are pressed. When
a key is pressed the name of the key that is pressed will
appear in the white box. When it is released, the name
will disappear. Perform this test on the rear display for
the rear keys, and the front display for the front keys.
(Figure 50)
Press the “Main” button to return to the “Regulated” or
“Manual” menu screen or the “Back” button to return to
the “More” menu screen.
Main
Diagnostics
Back
Y-Motion Sensor Test
SLOWLY push machine front and back.
Pulsing beep, increasing in frequency
as you push the machine faster.
No beep or solid beep as you move
the machine forward and back.
Passing Test:
Failing Test:
Main
Diagnostics
Back
Keypad Test
Press one of the handlebar keys.
The name of the key is shown below.
Passing Test:
No name or the wrong name below.
Failing Test:
Figure 50
Main
Diagnostics
Back
Motor Speed Sensor Test
The value stabilizes at 100.
Passing Test:
Remove bobbin case and top thread.
Clear all objects from the needle area.
Press Start/Stop on Handle.
173
Figure 48
Summary of Contents for Avante QM30235
Page 1: ...USER MANUAL 04 18 14 2014 Handi Quilter Inc Avanté 18 QM30235 version 2 0 ...