Diagnostics Menu
The Diagnostics Menu lists each of the diagnostics
tests available to help identify certain problems
with the HQ Fusion. Press any of the diagnostics
test buttons to perform that particular diagnostic
test. Then follow the instructions on the screen for
the test.
Press
X
to close this window or
Settings
to return to
the Settings screen.
Speed
10%
Diagnostics
Manual
Regulated
Motor Sensor
Needle Sensor
X Motion
Tension
Y Motion
Key Test
Speed
Settings
X
Motor Sensor Test
The Motor Sensor test helps to determine whether
there may be a problem with the HQ Fusion motor.
Rotating the front or back hand wheel should result
in a pulsing audible beep. If you get a constant
beep or no beep at all, the test has failed and the
machine should be inspected by a qualified
Handi Quilter repair technician.
Press
X
to close this window or
Back
to return to
the Diagnostics Menu.
Speed
35%
Needle Position
Manual
Regulated
80
Presets
35%
50%
70%
REC
Diagnostics
X
Diagnostics
Motor Sensor Test
Passing Test:
Rugular pulsing beeps as you rotate
the hand wheel.
Failing Test:
A solid tone or no beeping at all
as you rotate the handwheel.
Needle Sensor Test
The Needle Sensor test will indicate whether the
needle position sensor is functioning properly.
Rotating the front or back hand wheel should result
in a beep for half of a stitch cycle followed by no
beep for the other half. If you hear a constant beep
or no beep at all for a full 360° rotation of the hand
wheel, this indicates the test has failed and the
machine should be inspected by a qualified Handi
Quilter repair technician.
Press
X
to close this window or
Back
to return to
the Diagnostics Menu.
Speed
35%
Needle Position
Manual
Regulated
80
Presets
35%
50%
70%
REC
Diagnostics
X
Diagnostics
Needle Sensor Test
Passing Test:
Solid beep for 1/3 of a stitch cycle,
no beep for the rest of the cycle.
Failing Test:
No beep or solid beep as you rotate the
hand wheel one full revolution.
Rotate the hand wheel.