Needle-to-Hook Timing
(1 of 2)
1.
Remove the needle bar height gauge
and install the needle-to-hook timing
gauge. Make sure this timing needle
gauge is fully inserted.
This looks like a
needle with no eye or point.
2.
Make sure the tip of the hook touches
the
bent down tab
of the gauge. This is
necessary for both proper timing checks
and adjustments.
4.
Turn the hand wheel toward you
t
o
bring the needle bar down.
4
3
3. Power on the machine and
select center needle position.
Note: the
needle position will not change when the
needle is down, just when it is up!