Quick Reference Guide Handicare 2000
23
Lift does not move in either dir
ection
Code: Flat line (on char
ge) Code: 2 (of
f char
ge)
Connect the molex testing link
The voltage between M7-2 and gr
ound is not 4,5 V
The voltage between M7-2 and gr
ound is 4,5 V
The voltage between M7-1 or M7-3 and gr
ound is not
4,5 V when calling the lift
The main boar
d P1 is faulty
The lift is on the end position go to Lift does not move
in 1 dir
ection on page 25
Ther
e is a br
eak in the curr
ent between:
M7-2,U1-2,U2-2,U6-2,U18, U19,U12-2, U13-2
This Main Boar
d P1 is faulty
The joystick is faulty
One of the armr
ests is in the folded position
An armr
estswitch S29 or S30 is faulty
Summary of Contents for 2000
Page 1: ...Handicare 2000 QUICK REFERENCE GUIDE VERSION 2 1...
Page 2: ...2...
Page 4: ......
Page 42: ...Quick Reference Guide Handicare 2000 39...
Page 43: ......
Page 44: ......